Redline Communications Inc. SC1000E Manual Do Utilizador
User
BASE
STATION
Manual
Doc #70-00100-01-00-DRAFT
Proprietary Redline Communications © 2009
Page 25 of 60
January 7, 2009
Table 11: Phy - BBM: Front Panel Interface
Label Type
Description
Ethernet
RJ-45
8P8C
10/100Base-T Ethernet port. Used only for factory diagnostics.
Serial
D-Sub-9
RS-232 serial port. Used only for factory diagnostics.
3.5.3 LED Indicators
The module has the following front panel LED indicators:
Table 12: Phy - BBM: LED Indicators
LED Color
Description
Hot Swap
Blue
Hot-Swap Ready Indicator
Solid ON – the module is deactivated and can safely be extracted
Long Blink – module activation in progress
Short Blink – module deactivation in progress
Solid Off – the module is activated and unsafe for extraction
Solid ON – the module is deactivated and can safely be extracted
Long Blink – module activation in progress
Short Blink – module deactivation in progress
Solid Off – the module is activated and unsafe for extraction
Fault
Red
Out of Service Indicator
Solid ON – the module is out of service due to a hardware fault
detection or the module temperature is exceeding the critical
threshold
Long Blink – the module is out of service due to the missing
reference clock or missing synchronization frame from TCM
Solid Off – the module is functional
Solid ON – the module is out of service due to a hardware fault
detection or the module temperature is exceeding the critical
threshold
Long Blink – the module is out of service due to the missing
reference clock or missing synchronization frame from TCM
Solid Off – the module is functional
Active/
Standby
Green/
Amber
BBM Ready Indicator
Green Solid ON – the module is performing startup and is selected
as active (for redundant configurations)
Amber Solid ON – the module is performing startup and is selected
as standby for redundancy
Green Long Blink – the module is operational and selected as
active (for redundant configurations)
Amber Long Blink – the module is operational and selected as
standby for redundancy
Solid Off – the module is not receiving power from PWM
Green Solid ON – the module is performing startup and is selected
as active (for redundant configurations)
Amber Solid ON – the module is performing startup and is selected
as standby for redundancy
Green Long Blink – the module is operational and selected as
active (for redundant configurations)
Amber Long Blink – the module is operational and selected as
standby for redundancy
Solid Off – the module is not receiving power from PWM