Redline Communications Inc. SC1000E 用户手册

下载
页码 60
 
 User 
 BASE 
STATION 
Manual
 
 
Doc #70-00100-01-00-DRAFT 
Proprietary Redline Communications © 2009  
Page 25 of 60 
January 7, 2009 
Table 11: Phy - BBM: Front Panel Interface 
Label Type 
Description 
Ethernet 
RJ-45 
8P8C 
10/100Base-T Ethernet port. Used only for factory diagnostics. 
Serial 
D-Sub-9 
RS-232 serial port. Used only for factory diagnostics. 
 
3.5.3  LED Indicators 
The module has the following front panel LED indicators: 
Table 12: Phy - BBM: LED Indicators 
LED Color 
Description 
Hot Swap
 
Blue
 
Hot-Swap Ready Indicator 
Solid ON – the module is deactivated and can safely be extracted 
Long Blink – module activation in progress  
Short Blink – module deactivation in progress  
Solid Off – the module is activated and unsafe for extraction 
Fault
 
Red
 
Out of Service Indicator 
Solid ON – the module is out of service due to a hardware fault 
detection or the module temperature is exceeding the critical 
threshold 
Long Blink – the module is out of service due to the missing 
reference clock or missing synchronization frame from TCM 
Solid Off – the module is functional 
Active/
 
Standby
 
Green/
 
Amber
 
BBM Ready Indicator 
Green Solid ON – the module is performing startup and is selected 
as active (for redundant configurations) 
Amber Solid ON – the module is performing startup and is selected 
as standby for redundancy 
Green Long Blink – the module is operational and selected as 
active (for redundant configurations) 
Amber Long Blink – the module is operational and selected as 
standby for redundancy 
Solid Off – the module is not receiving power from PWM