Leviton Manufacturing Co. Inc. DDMX1 Manual Do Utilizador

Página de 18
PRELIMINARY
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the beneit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for ive years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option. For details 
visit
  www.leviton.com or call 1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating 
conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and itness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and itness for a particular purpose, 
is limited to ive years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or proits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
 ADVANCED PROGRAMMING FEATURES
Deinition of A Modes
A-1)
  
N/A
A-2)
  
Maximum Fan Speed: Sets the maximum fan speed level.
A-3)
   Minimum Fan Speed: Sets the minimum fan speed level.
A-4)
  
Preset ON Level: Sets the turn on fan speed level regardless of  
the previous set fan speed level.
Deinition of B Modes
B-1)
  
N/A
B-2)
  
N/A
B-3)
  
LED Options: Sets the time period in seconds the Locator LED  
and Brightness display will stay on before extinguishing.
B-3)
  The Locator LED will blink 3 times per second to indicate Program 
Mode B-3, LED Options. To change the LED Options settings, use 
the Fan Speed Bar to move the LED to the desired preset setting 
according to the LED Options Chart. By tapping the Top of the 
Rocker this setting will automatically be saved and the device will exit 
Programming Mode B.
Program Mode A
To enter Program Mode A:
Press and hold the TOP of the Rocker and the TOP of the DIM/BRIGHT 
Bar simultaneously for 5 seconds until the Locator LED begins to blink.
LED 7
Fan
Speed
Bar
Locator LED
LED 1
Deinition of LEDs
Bottom LED = LED 1
Top LED = LED 7
NOTES:
•  The device will exit programming 
mode after 3 minutes of inactivity.
•  Pressing the TOP of the Rocker at 
any time during programming will 
advance the device to the next 
programming mode.
Fan Speed Bar
INCREASE:
Press the TOP half of the Fan Speed Bar – Fan speed increases to 
desired level.
DECREASE:
Press the BOTTOM half of the Fan Speed Bar – Fan speed decreases 
to desired level. If you continue to hold, the fan speed level decreases to 
the minimum level and then turns OFF.
NOTE:
 When the fan is OFF you can change the fan speed level that 
the fan will turn ON to using the Fan Speed Bar. If there is a power 
outage, when the power is restored, the fan speed will return to the last 
setting before the power interruption.
NOTE:
 The locator light will illuminate when 
the load is in the OFF position to facilitate 
access in the dark.
NOTE:
 If using the fan speed control in a 
3-way application, the fan will turn ON at the 
speed set on fan speed control bar. The fan 
can be controlled from either the fan speed 
control, the remote location or the mobile 
device app.
Push Pad (Default settings)
Turn ON from OFF position:
Tap TOP of Rocker: Fan turns ON to preset 
level.
Turn OFF from ON position:
Tap BOTTOM of Rocker. Fan turns OFF.
 OPERATION
LED Brightness 
Display
Fan Speed 
Bar
Rocker
Locator 
Light
Cleaning:
 Clean with a damp cloth. 
DO NOT
 use chemical cleaners.
Gently pull out 
from bottom
Air-Gap Switch:
 On the fan speed control only, 
engage the air-gap switch by gently pulling out 
from the bottom of the Fan Speed Bar until the 
bottom of the bar lifts completely out of the frame 
and a click is heard (refer to Figure). LED's will 
turn OFF. This will stop power to the ixture. After 
servicing is complete, press the Fan Speed Bar 
back into place for normal operation.
Download the Leviton Decora
®
 Digital Dimmer & Timer App for  
your device.
Android:  
Tap the Google Play Store icon on your phone or go to  
http://play.google.com on your computer and follow the 
instructions to obtain the app.
iPhone:  
Tap the App Store icon on your phone or access the app 
through your iTunes account on your computer.
Once you have downloaded the app, follow the instructions on the screen 
to pair your mobile device with your fan speed control. Once your mobile 
device is paired, use the following options to control your fan speed:
•  On - Off: Turns the fan speed control ON and OFF.
•  Schedule: Creates distinct ON/OFF events based on time and day. 
•  Sleep Timer: Sets countdown to turn fan speed control OFF.
Advanced Settings
  Device Options
  •  Hide LED Dim Bar: 
Turns LED Dim Bar OFF.
  •  Hide Status LED: 
Turns Status LED OFF.
  •  DST Offset Hours: 
Adjusts the Sunrise/Sunset time in hours.
  •  DST Offset Minutes: 
Adjusts the Sunrise/Sunset time in minutes.
  Fan Speed Options
  • Preset: 
Sets the fan speed level at which the fan turns ON.
  • Minimum: 
Sets a minimum fan speed level.
  • Maximum: 
Sets a maximum fan speed level.
DI-000-DDF01-02A-X0
•  Fan does not turn ON and Locator LED does not turn ON
  -  Circuit breaker or fuse has tripped.
  -  Fan is burned out.
  -  Neutral not wired to Fan Speed Control (White wire).
  -   Conirm that the device is being supplied from a 120V, 60 Hz AC 
source ONLY.
•   Remote does not operate fan
  -  Ensure that total wire length does not exceed 300 ft.
  -  Ensure wiring is correct.
 TROUBLESHOOTING
CONTROLLING YOUR FAN SPEED CONTROL WITH 
BLUETOOTH
®
•  Restore power at circuit breaker or fuse.
•  Press pad until locator light is OFF. Fan 
should turn ON. If the fan does not turn 
ON, press the TOP half of the Fan Speed 
Bar until the fan speed increases.
If the fan still does not turn ON, refer to 
the TROUBLESHOOTING section.
Testing your Fan Speed Control prior to 
mounting in wall box:
 
Step 5
•  Position all wires to provide room 
in outlet wall box for device.
•  Ensure that the word “TOP” is 
facing up on device strap.
•  Partially screw in mounting screws 
in wall box mounting holes.
NOTE:
 Dress wires with a bend as 
shown in diagram in order to relieve 
stress when mounting device.
 FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada 
should contact Leviton in writing at Leviton Manufacturing of Canada 
Ltd to the attention of the Quality Assurance Department, 165 
Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9
 or by 
telephone at 1-800-405-5320.
Fan Speed Control Mounting:
TURN OFF POWER AT  
CIRCUIT BREAKER OR FUSE.
 
Step 6
Installation may now be completed by 
tightening mounting screws into wall box. 
Attach wallplate.
Restore Power:
Restore power at circuit breaker or fuse. 
Installation is complete.
 
Step 7
NOTE: 
To pair your fan speed control with your mobile device, 
download the Leviton Decora
®
 Digital Dimmer and Timer app from the 
Google Play Store or your iTunes account. Contact Leviton’s Techline 
at 1-800-824-3005 or visit Leviton’s website at www.leviton.com for 
additional information.
This device complies with Part 15 of the FCC Rules. Operation is subject to 
following two conditions: (1) this device may not cause harmful interference, 
and (2) this device must accept any interference received, including 
interference that may cause undesired operation of the device.
This equipment has been tested and found to comply with the limits for a 
Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits 
are designed to provide reasonable protection against harmful interference 
in a residential installation. This equipment generates, uses, and can radiate 
radio frequency energy and, if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a particular 
installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment OFF 
and ON, the user is encouraged to try to correct the interference by one or 
more of the following measures:
• 
Reorient or relocate the receiving Antenna.
• 
Increase the separation between the equipment and the receiver.
• 
 Connect the equipment into an outlet on a circuit different from that to 
which the receiver is connected.
• 
Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION
Any changes or modiications not expressly approved by Leviton 
Manufacturing Co., Inc., could void the user's authority to operate the 
equipment.
 FCC COMPLIANCE STATEMENT
Copyright and Trademark Information
The Bluetooth
®
 word mark and logos are registered trademarks owned by 
Bluetooth SIG, Inc., used under license by Leviton.
Use herein of third party trademarks, service marks, trade names, brand 
names and/or product names are for informational purposes only, are/may 
be the trademarks of their respective owners; such use is not meant to imply 
afiliation, sponsorship, or endorsement.
No part of this document may be reproduced, transmitted or transcribed 
without the express written permission of Leviton Manufacturing Co., Inc.
For additional information, contact Leviton’s Techline at  
1-800-824-3005 or visit Leviton’s website at www.leviton.com
This product is covered by U.S. Patent No. 8,664,886 and corresponding 
foreign patents.
© 2015 Leviton Mfg. Co., Inc.
Program Mode B
To enter Program Mode B:
Press and hold the TOP of the Rocker and then the BOTTOM of the Fan 
Speed Bar for 5 seconds until the Locator LED and the TOP LED (LED 7) 
begin to blink.
A-2)
  Maximum Fan Speed Level: The Locator LED will blink 2 times per 
second to indicate the device is in Program Mode A-2, Maximum 
Fan Speed Level
.The default mode is 100% i.e. full fan speed. To 
change the fan speed level, use the Fan Speed Bar to move the 
corresponding LED to the desired discreet preset level according to 
the Maximum Fan Speed Chart. By tapping the TOP of the Rocker 
this setting will automatically be saved and the device will advance to 
the next Programming Mode, A-3, Minimum Fan Speed Level.
MAXIMUM FAN SPEED CHART
When indicator is at LED #
Fan speed is at
7
Max
5
High
3
Medium
1
Low
LED OPTIONS CHART
LED
Locator LED Timeout
LED Brightness Display Options
1
Active
Active
2
Active
Turns OFF 5 seconds after use
3
Turns OFF 5 seconds after use
Active
4
Turns OFF 5 seconds after use
Turns OFF 5 seconds after use
5
N/A
N/A
6
N/A
N/A
7
N/A
N/A
A-3)
  The Locator LED will blink 3 times per second to indicate the device is in 
Program Mode A-3, Minimum Fan Speed Level. The default Minimum 
fan Speed Level is LED 2. To change the Minimum Fan Speed Level 
from 1-50%, use the Fan Speed Bar. The fan speed will relect the 
minimum fan speed level selected. By tapping the TOP of the Rocker 
this setting will automatically be saved and the device will advance to the 
next programming mode, A-4, Preset ON Level.
A-4)
  The Locator LED will blink 4 times per second to indicate Program 
Mode A-4, Preset ON Level. To change the current Preset ON 
Level
 from 1-100%, use the Fan Speed Bar. If this feature is not 
desired, press and hold the BOTTOM half of the Fan Speed Bar 
until no LED is lit (default setting). By tapping the TOP of the Rocker 
this setting will automatically be saved and the device will exit 
Programming Mode A.
 IC COMPLIANCE STATEMENT
This device complies with Industry Canada licence-exempt RSS 
standard(s). Operation is subject to the following two conditions: (1) 
this device may not cause interference, and (2) this device must accept 
any interference, including interference that may cause undesired 
operation of the device.
If your fan speed control is not responding, or you are unable to control 
it after you have tried to Pair/Connect to it multiple times, it may be 
necessary to reset the fan speed control to its original factory settings. 
To accomplish this, proceed as follows:
On the fan speed control, hold the TOP of the rocker until the locator LED 
starts to blink. The fan speed control is now reset. Once the fan speed 
control is reset, it may be necessary to re-pair with the your application.
FACTORY DEFAULT