Power Supply
ALS1-US needs to be connected to a power supply at the SMT application interface - 4 lines 
each BATT+ and GND. There are two separate voltage domains for BATT+:
• BATT+_RF with 2 lines for the RF power amplifier supply 
• BATT+ with 2 lines for the general power management. 
The main power supply from an external application has to be a single voltage source and has 
to be expanded to two sub paths (star structure). Each voltage domain must be decoupled by 
application with low ESR capacitors (
>
 47µF MLCC @ BATT+; 
>
 4x47µF MLCC @ BATT+_RF) 
as close as possible to LGA pads. 
 shows a sample circuit for decoupling capacitors 
for BATT+.
Figure 2:  
Decoupling capacitor(s) for BATT+
The power supply of ALS1-US must be able to provide the peak current during the uplink trans-
mission. 
All key functions for supplying power to the device are handled by the power management IC. 
It provides the following features:
• Stabilizes the supply voltages for the baseband using switching regulators and low drop lin-
ear voltage regulators.
• Switches the module's power voltages for the power-up and -down procedures.
• Delivers, across the VEXT line, a regulated voltage for an external application.
• LDO to provide SIM power supply.
BATT+
2
2
Decoupling capacitors
e.g. 47µF X5R MLCC
4x
GND
BATT+
BATT+_RF
Module
SMT interface
1x