8 Installing a pRRU3902 or pRRU3911 or 
pRRU3911+WIFI 
 
Issue 08 (2016-05-30) 
Huawei Proprietary and Confidential         
Copyright © Huawei Technologies Co., Ltd. 
124 
 
----End 
8.3.3 Installing a pRRU on a Ceiling 
This section describes how to install a pRRU on the ceiling, such as the concrete ceiling, 
when the ceiling has adequate load bearing capacity and installation space. 
Context 
 
If the pRRU is installed on a ceiling, the temperature of the ceiling may increase by a maximum of 30 
degrees. Therefore, whether a pRRU can be installed on a ceiling depends on the ceiling material. 
Procedure 
Step 1  Determine the position for installing the pRRU based on the construction blueprint and the 
clearance requirements. 
 
For details about the clearance requirements, see 8.1.3 Space Requirements. 
Step 2  Place the mounting bracket in the installation position against the ceiling. Then, level the 
mounting bracket and use a marker to mark four anchor points. See Figure 8-11. 
Figure 8-11
 Anchor points on the pRRU mounting bracket 
 
(1) Ceiling 
(2) Mounting bracket 
(3) Anchor point 
 
 
To prevent inhalation or eye contact with dust, take adequate preventive measures when drilling holes. 
Step 3 
Use a hammer drill with φ6 bore to drill holes at the marked anchor points, as shown in 
Figure 8-12. Use a vacuum cleaner to clean the dust inside and around the holes and measure 
the distance between them. If they are inaccurately positioned, re-measure and re-drill the 