3.  FUNCTIONAL DESCRIPTION 
 
Transmitter Operation 
 
 
 
•  System power is initially off.  Activation of any switch attached to VSW will power up the coder. 
•  If a switch is on when the battery pack is installed, the coder will light the Red LED and prevent 
operation until the switch is released or fixed. 
•  After activation, the coder will automatically power down while idle.  This timeout is adjustable via 
H-Link. 
•  The coder is a passive transmitter which enters transmission cycles based on the programmed duty 
cycle.  
•  Each transmission cycle produces two transmissions.  One occurs on the primary channel while the 
other occurs on the secondary channel.  Immediately after each transmission, the coder listens for 
feedback from the decoder for up to 3ms.  The Green or Red LED will toggle for each frame that is 
transmitted. 
•  After each transmit/receive pulse, the radio is disabled to save power. 
•  Pressing the stop button (DK31/DK32) will disconnect the battery and force stop frames to be sent 
until the unit discharges. 
•  DK1 is a start function.  This button can be used to reset receiver errors (Overload/ Main Contact 
error) or to perform the learning operation. 
•  DK3-18 are regular digital channels. 
•  DK19-22 can be used as a 4 bit grey code trigger or regular digital channels. 
•  If the battery level drops below the set low-voltage level, the coder will light the Red LED. 
•  If the battery level drops below the critical level, the transmitter will turn off the Green LED and 
blink the Red Led while sending Stop frames. The power will be turned off after 2 seconds or after 
all switches are released.