e.1) The voltage on contact C3 (CLK) of the SIM/ME interface shall be between  0.3V and 
 
+0.47V for a current of  20 µA in low state and between 1.21V and Vcc +0.3V for a 
 
current of +20 µA in high state when the interface is in 1.8V operation mode. 
e.2) The rise and the fall time of the clock signal shall not exceed 50 ns when the interface is 
 
in 1.8V operation mode. 
 
e.3) The cycle ratio of the clock signal shall be between 40 % and 60 % of the period, in 
 
steady state when the interface is in 1.8V operation mode. 
 
e.4) The frequency of the clock signal shall be between 1 MHz and 4 MHz when the interface 
 
is in 1.8V operation mode. 
 
e.5) The voltage on contact C3 (CLK) of the SIM/ME interface shall be between  0.3V and 
 
+0.6V for a current of  20 µA in low state and between 1.9V and Vcc +0.3V for a current 
 
of +20 µA in high state when the interface is in 3V operation mode. 
 
e.6) The rise and the fall time of the clock signal shall not exceed 50 ns when the interface is 
 
in 3V operation mode. 
 
e.7) The cycle ratio of the clock signal shall be between 40 % and 60 % of the period, in 
 
steady state when the interface is in 3V operation mode.  
 
e.8) The frequency of the clock signal shall be between 1 MHz and 4 MHz when the interface 
 
is in 3V operation mode. 
 
•  27.17.2.5  Electrical tests on contact C7 (IO) 
 
e.1) ME receiving state A (low state): 
 
With an imposed voltage of 0V the current flowing out of the ME shall not exceed 1 mA 
 
when the ME is in 3V operation mode. 
 
e.2) ME transmitting state A (low state): 
 
The voltage shall be between  0.3V and 0.4V when a current of 1 mA flowing into the ME 
 
is applied when the ME is in 3V operation mode. 
 
e.3) ME transmitting or receiving state Z (high state): 
 
The voltage shall be between 0.7*Vcc and Vcc + 0.3V when a current of 20 µA flowing 
 
out of the ME is applied when the ME is in 3V operation mode. 
 
e.4) The rise time and the fall time of the I/O signal shall not exceed 1 µs when the ME is in 
 
3V operation mode. 
 
e.5) ME receiving state A (low state): 
 
With an imposed voltage of 0V the current flowing out of the ME shall not exceed 1 mA 
 
when the ME is in 1.8V operation mode. 
 
e.6) ME transmitting state A (low state): 
 
The voltage shall be between  0.3V and 0.3V when a current of 1 mA flowing into the ME 
 
is applied when the ME is in 1.8V operation mode. 
 
e.7) ME transmitting or receiving state Z (high state): 
 
The voltage shall be between 0.7*Vcc and Vcc + 0.3V when a current of 20 µA flowing 
 
out of the ME is applied when the ME is in 1.8V operation mode. 
 
e.8) The rise time and the fall time of the I/O signal shall not exceed 1 µs when the ME is in 
 
1.8V operation mode.