Novatel Wireless NRM-EU870D Manual Do Utilizador

Página de 85
 
 
43
 
Novatel Wireless  
 
 
 
 
 
 
Revision 1  
 
HW Parameters  
The System Management Bus (SMBus) is a two-wire interface through which various system 
component chips can communicate with each other and with the rest of the system. It is based on 
the principles of operation of I 2 C. 
 
The reader is referred to SMBus reference as described in the System Management Bus 
(SMBus) Specification, Version 2.
0 for further details on its operation.  
 
The peripheral board communicating to the SMBus must provide pull-ups to 2.6V. It is 
recommended that a 2.7 K ohm pull connected to 2.6 Volt rail.   
 
DC parameters 
Symbol  
Parameter  
 
 
        Limits  
 
Units  
    Min 
 
Max 
VIL  
Data, Clock Input Low Voltage   
- 0.3 
0.86   V 
VIH  
Data, Clock Input High Voltage    
1.78 
2.77   V 
VOL   Data, Clock Output Low Voltage  
  0 
0.45   V 
ILEAK   Input Leakage    
 
 - - 
±5  
μA 
VDD   Nominal bus voltage  
  
2.47 
2.73 
V  
 
Table 2: SMBus DC specification
 
SM Bus interface Board  
 
Pull up resistors on both lines (SMB_CLK and SMB_DATA) and solid ground connections are 
necessary. Without proper pull up values and good ground and instability in communication will 
be experienced. 
 
As illustrated below it is recommended that a 2.7 K ohm pull connected to 2.6 Volt rail.   
Figure 9:  SM Pull-up Configuration 
 
Host Board
  
 
Novatel PCI Express Mini Card
 
 
Host Board
  
 
Novatel PCI Express Mini Card
 
 
 
GPIO
2.6 V
 
 
2.7K
 
Peripheral 
  (Slave) 
 
SMB_CLK Pin (32)
EU8X0/E725 
 
SMB_DATA Pin (30)
 
GPIO
2.6 V
EU8X0/E725 
 
2.7K
 
Peripheral 
  (Slave)