Fusion Wideband Main Hub Rear Panel
This interface can both generate two source contact alarms (Fault and Warning) and
sense 3 single external alarm contacts (Alarm Sense Input 1 through 3).
sense 3 single external alarm contacts (Alarm Sense Input 1 through 3).
3.3.1.2
N-type Female Connectors
There are two 50 Ohm N-type connector pairs for each of the 3 bands on the rear
panel of the Hub:
panel of the Hub:
• The
DOWNLINK
connector receives downlink RF signals from a repeater, local
base station, or FlexWave Focus system.
• The
UPLINK
connector transmits uplink RF signals to a repeater, local base sta-
tion, or FlexWave Focus system.
CAUTION:The
UPLINK
and
DOWNLINK
ports cannot handle a DC power
feed from the local base station. If DC power is present, a DC block must be
used or the Fusion Wideband hub may be damaged.
used or the Fusion Wideband hub may be damaged.
5
Warning Source Contact (negative connection)
6
DC Ground (common)
7
Fault Source Contact (positive connection)
8
Alarm Sense Input 1
9
Fault Source Contact (negative connection)
Table 3-3
9-pin D-sub Pin Connector Functions
Pin
Function