ADC Telecommunications Inc. F0684-112 Manual Do Utilizador

Página de 236
Main Hub Specifications
3-10
InterReach Fusion Wideband Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620616-0-20 Rev F
3.4
Main Hub Specifications
Table 3-4
Main Hub Specifications
Specification
Description
Enclosure Dimensions (H 
 W 
 D)
a
a. Excluding angle brackets for the 19” rack mounting of the Hub.
89 mm x 438 mm x 381 mm (3.5 in. x 17.25 in. x 15 in.) 2U
Weight
<5.5 kg (<12 lb)
Operating Temperature
0° to +45°C (+32° to +113°F)
Non-operating Temperature
–20° to +85°C (–4° to +185°F)
Operating Humidity, non-condensing
5% to 95%
External Alarm Connector 
(contact closure)
1 9-pin D-sub, female
Maximum: 40 mA @ 40V DC
Typical: 4 mA @ 12V DC
ADMIN/LAN Interface Connector
1 RJ-45, female
1 9-pin D-sub, male for optional modem
Fiber Connectors
4 Pair, SC/APC
b
b.  It is critical to system performance that only SC/APC fiber connectors are used throughout the fiber network, including 
fiber distribution panels.
RF Connectors
4 N
c
, female (50 Ohm), 1 Downlink/Uplink pair per band
c. 6 N, female connectors for FSN-W2-MH-1, FSN-W2-MH-2, and FSN-W2-MH-3
NOTE: The Fusion Wideband One Port Main Hub 
(PN: FSN-W1-MH-1P and FSN-W2-MH-1P) configuration is 
a cost reduced version of the Fusion Wideband Main Hub and 
supports only one Expansion Hub (up to 8 RAUs).
LED Fault and Status Indicators
Unit Status (1 pair):
• Power
• Main Hub Status
Downstream Unit/Link Status (1 per fiber port):
• Link/E-Hub/RAU
AC Power
Rating 100/240V AC, 1A, 50-60 Hz
Operating Range: 90-132V AC/170-250V AC auto-ranging
Power Consumption (W)
30
MTBF
133,829 hours