Silverstone SST-DA750 Manual Do Utilizador
7
4.2 Over Voltage Protection
The power supply shall shut down in a latch off mode when the output voltage exceeds the over voltage
limit shown in Table 15.
limit shown in Table 15.
Voltage
Minimum
Maximum
Shutdown
Mode
+5V +5.7V
+6.5V
Latch
Off
+3.3V +3.9V
+4.5V
Latch
Off
+12V +13.3V
+14.5V
Latch
Off
5VSB 5.7
6.5
Auto
recovery
Table 15 –Over Voltage protection
4.3 Short Circuit Protection
The power supply shall shut down in a latch off mode when the output voltage is short circuit.
5. Environmental Requirements
5.1 Temperature
Operating Temperature Range:
0
°C ~ 50°C (32°F~ 122°F)
Non-Operating Temperature Range: -40°C ~ 70°C (-40°F~ 158°F)
5.2 Humidity
Operating Humidity Range:
20% ~ 90%RH non-condensing
Non-Operating Humidity Range:
5% ~ 95%RH non-condensing