6. Agency Requirements 
6.1 Safety Certification. 
Product Safety:   
UL 60950-1 2000Edition, IEC60950-1, 3
rd
 Edition
EU Low Voltage Directive (73/23/EEC) (CB) 
TUV, CCC 
RFI Emission: 
FCC Part15 ( Radiated & Conducted Emissions )
CISPR 22,3
rd
 Edition / 
EN55022: 1998 + A1: 2000
PFC Harmonic: 
EN61000-3-2:2000
 
Flicker: 
EN61000-3-3: 1995 + A1: 2002
 
Immunity against: 
-Electrostatic discharge: 
-Radiated field strength: 
-Fast transients: 
-Surge voltage: 
-RF Conducted 
-Voltage Dips and Interruptions 
EN55024: 1998 + A1: 2001 and A2: 2003 
 
-IEC 61000-4-2 
-IEC 61000-4-3 
-IEC 61000-4-4 
-IEC 61000-4-5 
-IEC 61000-4-6 
-IEC 61000-4-11   
 
Table 16 –
Safety Certification
 
 
6.2 AC Input Leakage Current 
Input leakage current from line to ground will be less than 3.5mA rms. Measurement will be made at 
240 VAC and 60Hz. 
7. Reliability 
7.1 Mean Time Between Failures (MTBF) 
The MTBF of the power supply shall be calculated utilizing the Part-Stress Analysis method of 
MIL217F or Bell core RPP. The calculated MTBF of the power supply shall be greater than 100,000 
hours under the following conditions: 
Full rated load 
120V AC input 
Ground Benign 
        25
°C 
7.2 Warranty 
Three (3) years manufacture's warranty.   
 
 
Technical information in this specification is subject to change without notice. 
The revision of specification will be marked on the cover.