Adtran TRC4108 Manual Do Utilizador

Página de 60
Section 3  Engineering Guidelines
TRACER 4108/4208 System Manual
 26
© 2003 ADTRAN, Inc.
612804208L1-1B
1.
EQUIPMENT DIMENSIONS
The TRACER 4108/4208 unit is 17.12” W, 10.80” D, and 1.72” H and can be used in 19 or 23-inch rack-mount 
configurations.
2.
POWER REQUIREMENTS
The TRACER 4108/4208 system has a maximum power consumption of 21 Watts (TRACER 4108) and 18 Watts 
(TRACER 4208) and a maximum current draw of 0.86 Amps (at 21 VDC).
3.
REVIEWING THE FRONT PANEL DESIGN
The front panel contains 
RSSI
 and 
TX PWR
 monitoring interfaces, a 
GND
 interface for reference with the 
monitoring interfaces, and status LEDs to provide visual information about the TRACER 4108/4208 system. 
Figure 1 identifies the various bantam interfaces and the LEDs on a TRACER 4208 front panel. The TRACER 
4108 front panel is identical (with the TRACER 4108 product label).
Figure 1.  TRACER 4208 Front Panel Layout
RSSI Monitoring Interface
The RSSI voltage is a function of the signal strength at the receiver and is used to measure the received signal 
strength. RSSI varies approximately from 0 to 5 Volts (V).An RSSI Calibration sheet is shipped with the system 
to provide the installer a cross-reference between actual received signal level (in dBm) and RSSI voltage. This 
sheet is useful for verifying link budget calculations and ensuring proper equipment installation.
TX PWR Monitoring Interface
The 
TX PWR
 voltage is a function of the selected transmit power level. This voltage ranges approximately from 
0 to 5V, with 0V corresponding to +5 dBm (3 milliwatts) and 5V corresponding to +20 dBm
(100 milliwatts).
ALARM
T1A T1B T1C T1D T1E T1F T1G T1H
TRACER 4208
Status LEDs
TX PWR
RSSI
GND