Adtran TRC4206 Manual Do Utilizador

Página de 66
TRACER 4206 System Manual
Section 4, Network Turnup Procedure
612804206L1-1A
© 2002 ADTRAN, Inc.
35
4.
CHANNEL SELECTION
The FCC has allocated 125 MHz of spectrum in the band in which the TRACER 4206 operates. Figure 1 
illustrates the bandwidth division. 
Figure 1.  Bandwidth Division
To designate the utilization of the ISM bandwidth, there are two different channel plans, labeled A and B.  
The letter of each channel plan setting is preset by the factory and refers to the physical configuration of 
the diplexer filter inside the environmental housing.  Each channel is then divided into three Bandplans (1, 
2 or 3).  The Bandplans must be the same for the local and remote TRACER 4206.  For example, the 
transmitter at one end of the link will transmit in Bandplan 1 of the lower portion of the spectrum and 
receive in Bandplan 1 of the upper portion.  Consequently, the receiver at the other end should receive in 
Bandplan 1 of the lower portion and transmit in Bandplan 1 of the upper portion.
The letter of the channel plan (A or B) must be different on both ends and the number of the Bandplan (1, 
2, or 3) must be the same on both ends. Shipment of a link will consist of one Plan A, Bandplan 2, and Plan 
B, Bandplan 2, unit.
The channel plan (A or B) of the unit may be changed in the field if necessary by rewiring the internal 
diplexer. Contact ADTRAN Technical Support for more information on this procedure.
5.
GROUNDING INSTRUCTIONS
The following provides grounding instruction information from the Underwriters’ Laboratory UL 60950 
Standard for Safety of Information Technology Equipment Including Electrical Business Equipment, of 
December, 2000.
An equipment grounding conductor that is not smaller in size than the ungrounded branch-circuit supply 
conductors is to be installed as part of the circuit that supplies the product or system. Bare, covered, or 
insulated grounding conductors are acceptable. Individually covered or insulated equipment grounding 
conductors shall have a continuous outer finish that is either green, or green with one or more yellow 
stripes. The equipment grounding conductor is to be connected to ground at the service equipment.
The attachment-plug receptacles in the vicinity of the product or system are all to be of a grounding type, 
Channel A
5739
5725
5787
5850
5749
5758
MHz
MHz
Band 3
Band 2
Band 1
Channel B
5819
5829
5838
Band 3
Band 2
Band 1