Adtran TRC4208L1 Manual Do Utilizador

Página de 60
Section 5  User Interface Guide
TRACER 4208 System Manual
 50
© 2003 ADTRAN, Inc.
612804208L1-1A
The minimum received signal level (
MIN RSL
) is represented as a numerical value from 0 to 255 with 0 
corresponding to no receive power and 255 corresponding to an extremely strong signal. The minimum 
received signal level is directly related to RSSI.
The error count and received signal level for the most recent 24 hours are recorded and displayed on the 
right side of the page. The left side of the page displays the 24 hour totals for the most recent 7 days. 
> T1
X
 S
TATUS
/C
ONFIGURATION
/L
OOPBACK
Figure 7 shows the T1x Status/Configuration/Loopback menu page, which displays a real-time graphical 
representation for the T1x link (using data from both the local and remote TRACER 4208 units) is 
displayed on this page. T1x operational configuration parameters and testing functions are configured from 
this menu.
Figure 7.  T1x Status/Configuration/Loopback
Press <N> to view the next 8 hours worth of 15-minute totals and <P> to view the 
previous 8 hours.
Press <L> from any menu in the TRACER 4208 VT100 menu structure to access the 
TRACER Link Performance History menu page.
The following menus for the T1x Staus/Configuration/Loopback and T1x Performance 
History apply to all eight available T1 interfaces (A through H).