Adtran TRC582TM1 Manual Do Utilizador

Página de 64
TRACER 2xT1 User’s Manual
61280003L2-1B
Section 3  Operation
30
Preliminary
Main Menu Page
Pressing “M” on any screen will take the user to the Main Menu, from which the subsequent screens can
be accessed.
T1 Status Page
The status of the two T1 interfaces is displayed on this screen.  Information such as alarm status, T1
receive levels, line coding, and framing type are shown.  This is a status screen only.
Figure 3-5. T1 Status Page
TRACER T1 Status Menu
Site: Adtran
                        T1A                         T1B
Loop/Normal State       Normal                      Normal
Received Signl Lvl      +2dB to -7.5dB              Less than -22.5dB
RX LOS (Red) Alarm      No                          Yes
RX AIS (Blue) Alarm     No                          No
RX Yellow Alarm         No                          No
TX AIS (Blue) Alarm     No                          Yes
Framing                 ESF (*)                     ESF (*)
Line Code               B8ZS (*)                    B8ZS (*)
Line Build Out          DS1 0dB (*)                 DS1 0dB (*)
(*) Indicates last set by front panel. Otherwise last set by terminal.
===============================================================================
Press ‘m’ - Main menu
Figure 3-4. Main Menu Page
TRACER Main Menu, Rev: A, 12/13/99 16:04:00
Site: Adtran
1) T1 Status Page
2) Link Performance History
3) T1A Performance History
4) T1B Performance History
5) Alarm Page
6) Test Menu
7) Configuration Menu
8) Remote Access
===============================================================================
Press ESC for System Status: