1.
EQUIPMENT DIMENSIONS
The TRACER 6200 Indoor Unit (IDU) is 17.2-inch (43.7 cm) W, 11.4-inch (28.9 cm) D, and 1.7-inch
 
(4.4 cm) H, weighs 5 lbs (2.3 kg), and can be used in rackmount configurations. The Outdoor Unit (ODU) 
is 10.24-inch (26.01 cm) W, 4.78-inch (12.14 cm) D, and 12.74-inch (32.36 cm) H, weighs 9.5 lbs (4.3 kg), 
and can be mounted using standard U-bolts.
2.
POWER REQUIREMENTS
The TRACER 6000 Series system has a maximum power consumption of 25 W and a maximum current 
draw of 1.8 A (at 21 VDC).
3.
REVIEWING THE FRONT PANEL DESIGN
The TRACER 6200 front panel contains an 
RSSI
 monitoring interface, a 
GND
 interface for reference
 
with RSSI, a 
TEST
 interface for factory use only, a DB-9 
CRAFT
 port for management and configuration, 
and an 
AUX RS232
 interface (RJ-45) that provides an end-to-end serial port interface (at 9600 bps), and 
status LEDs to provide visual information about the TRACER system. Figure 1 identifies the various 
interfaces and the LEDs and Table 1 provides a brief description of each interface.
Figure 1.  TRACER 6200 Front Panel Layout
Table 1.  TRACER 6200 Front Panel Description
1
 
1
Detailed discussions (including pinouts) of front panel components (where applicable) follow the table.
Name
Connector
Description
A
RSSI
bantam
DC voltage indicating strength of the received signal at the 
antenna
B
Status LEDs
N/A
Visual status information about the system
C
GND
bantam
Ground reference for the RSSI interface
D
Test
3.5 mm mini-jack
Factory use only
E
AUX RS232
RJ-45
Serial interface for a 9600 bps connection between the 
local and remote systems over the RF link
F
CRAFT PORT
DB-9
RS-232 interface for connection to a VT100 terminal or PC 
with terminal emulation software
TRACER 6200
B
C
A