Adtran TRC6410 Manual Do Utilizador

Página de 130
TRACER 6000 Series Integrated System Manual
Section 8  Troubleshooting Guide
612806420L1-1D
Copyright © 2005 ADTRAN, Inc.
125
RF LOW LED
If the 
RF LOW
 LED is 
ON
 (solid red), the received signal is approaching 0 V of RSSI. This condition is 
typically indicative of a path or installation problem.
Recommended Actions:
1.
Verify the far-end transmitter power setting is the value that the link planning budget allows.
2.
Check all coaxial cable connectors for solid connections. Check for water and corrosion around any of 
the connectors. If water is apparent in the coaxial connectors, replace the coaxial cable and the 
connectors, making sure to properly weatherproof the replacements.
3.
Verify the RF signal path by verifying the antenna alignment.
4.
Check the integrity of lightning arrestors.
T1 Interface Alarms
All active T1 alarms are displayed in the 
T1
X
 S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 menu page.To identify the 
T1 interface in alarm and the specific alarm present, display the 
T1(
X
) S
TATUS
 screens and check the 
T1(
X
I
NTERFACE
 A
LARMS
 field.
Recommended Actions:
1.
Display the T1(
X
) S
TATUS
 screen and check the T1(
X
) I
NTERFACE
 A
LARM
 field to identify the active alarm. 
2.
Follow the steps below for the appropriate alarm.
LOS Alarm or Red Alarm
LOS A
LARM
 and 
R
ED
 A
LARM
 are indications that the TRACER 64x0 may be unable to detect a viable T1 
received signal from the connected T1 equipment. This error may be due to a degraded signal or no 
signal, or may be caused by improper framing.
Recommended Actions:
1.
Verify that the T1 cable is connected to the T1 interface on the TRACER 64x0.
2.
Verify the connections at the opposite end of the T1 cable.
3.
Verify that the framing mode (D4 or ESF) is the same for both the TRACER 64x0 and the T1 
equipment.
Yellow Alarm
A Yellow Alarm is generated by the attached equipment. When the attached equipment’s T1 interface is 
in Red Alarm, the TRACER 64x0 generates a Yellow Alarm.
Recommended Actions:
1.
Follow the troubleshooting steps for Red Alarm, but do so at the attached equipment.
Blue Alarm 
A remote alarm (alarm indication signal or AIS) is generated by the attached equipment. The root cause 
must be determined at the attached equipment. A typical cause of a blue alarm is a lack of input to a 
CSU.
Recommended Actions:
1.
Verify the input to any attached data equipment.