BPV
Bipolar violations (BPVs) indicate an improper configuration or faulty wiring.
Recommended Actions:
1.
Verify the TRACER 64x0 unit and the attached equipment are configured for the same line coding 
(B8ZS or AMI).
2.
Verify the cable connections for the T1 interface are solid.
E1 Interface Alarms 
All active E1 alarms are displayed on the 
E1
X
 S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 menu page. To identify 
the E1 interface in alarm and the specific alarm present, display the 
E1(
X
) S
TATUS
 screens and check the 
E1(
X
) I
NTERFACE
 A
LARMS
 field.
Recommended Actions:
1.
Display the E1(
X
) S
TATUS
 screen and check the E1(
X
) I
NTERFACE
 A
LARM
 field to identify the active 
alarm. 
2.
Follow the steps below for the appropriate alarm.
LOS Alarm (Loss of Signal)
LOS A
LARM
 is an indication that the TRACER 64x0 may be unable to detect a viable E1 received 
signal from the connected E1 equipment. This error may be due to a degraded signal or no signal, or 
may be caused by improper framing.
Recommended Actions:
1. Verify that the E1 cable is connected to the E1 interface on the TRACER 64x0.
2. Verify the connections at the opposite end of the E1 cable.
3. Verify that the framing mode (framed, multiframed, or unframed) is the same for both the
 
TRACER 64x0 and the E1 equipment.
AIS Alarm 
A remote alarm (alarm indication signal or AIS) is generated by the attached equipment. The root 
cause must be determined at the attached equipment. A typical cause of a blue alarm is a lack of input 
to a CSU.
Recommended Actions:
1.
Verify the input to any attached data equipment.
LCV
Line code violations (LCVs) indicate that the received E1 stream contains an invalid line code and are 
generally caused by an improper configuration or faulty wiring.
Recommended Actions:
1.
Verify the TRACER 64x0 unit and the attached equipment are configured for the same line coding 
(HDB3 or AMI).
2. Verify the cable connections for the E1 interface are solid.