Adtran TRC6410 Manual Do Utilizador

Página de 130
Section 5  User Interface Guide
TRACER 6000 Series Integrated System Manual
 64
Copyright © 2005 ADTRAN, Inc.
612806420L1-1D
> S
YSTEM
 C
ONFIGURATION
 > CRAFT P
ORT
 B
AUD
Specifies the baud rate of the port. Select either 
9600
 (default), 
19200
38400
57600
, or 
115200
 bps. If 
you are using the 
CRAFT
 port for modem access, ensure that the 
CRAFT
 port rate matches the modem 
baud rate.
> S
YSTEM
 C
ONFIGURATION
 > I
NACTIVITY
 L
OGOUT
This option defines the amount of time in minutes the user can stay connected without any activity on the 
CRAFT
 port before the user is automatically logged out of the system. Select one of the following: 
MIN
,
 
10 
MIN
 
(default),
 15 
MIN
30 
MIN
45 
MIN
60 
MIN
, or 
O
FF
.
> S
YSTEM
 C
ONFIGURATION
 > P
ASSWORD
Sets the password for password protection of the TRACER 64x0 terminal interface. Enter up to eight 
alphanumeric characters. The system password is case sensitive.
> S
YSTEM
 C
ONFIGURATION
 > P
ERFORMANCE
 S
TATS
 (C
LEAR
)
Resets all system error counters for the TRACER 64x0.
> S
YSTEM
 C
ONFIGURATION
 > F
ACTORY
 D
EFAULTS
Resets the system to the factory default settings. The configured 
IP A
DDRESS
S
UBNET
 M
ASK
, and 
D
EFAULT
 
G
ATEWAY
 
are not defaulted during a factory default. When you select this command, the following 
confirmation message appears: 
Are you sure you want to restore factory Defaults? Y or N
Press 
Y
 to restore factory defaults or 
N
 to cancel this command.
Changes to the 
I
NACTIVITY
 L
OGOUT
 setting do not apply to the current session. All changes 
take affect at the next login to the system menus.
The default password for the TRACER 64x0 is password.
The 
T
OTAL
 A
CTIVE
 C
HANNELS
 parameter (on the Datapath Provisioning menu page) is 
reset to the factory default value (
8
). Performing a factory default on any system with less 
than eight active channels results in an RF link loss.