Adtran TRC6410 Manual Do Utilizador

Página de 130
TRACER 6000 Series Integrated System Manual
Section 5  User Interface Guide
612806420L1-1D
Copyright © 2005 ADTRAN, Inc.
65
> RF L
INK
 C
ONFIGURATION
Figure 5 shows the TRACER 64x0 RF Link Configuration menu page, which contains the transmit and 
receive power settings and band plan configuration for both the local and remote units.
Figure 5.  RF Link Configuration
> RF L
INK
 C
ONFIGURATION
 > RX P
OWER
Displays the real-time receiver levels (for both the local and remote units) in dBm and a visual 
approximation using a series of symbols (
#
). The more symbols (
#
) displayed, the stronger the signal. 
Real-time receiver levels are displayed within ±5 dBm accuracy and can vary with extreme temperatures. 
If the link is down in either direction and remote end data is unavailable, 
D
ATA
 N
OT
 A
VAILABLE
 displays in 
place of the symbols (
#
). This parameter is display only. 
> RF L
INK
 C
ONFIGURATION
 > TX P
OWER
Allows the transmitter levels (for both the local and remote units) to be adjusted. The current transmitter 
level is displayed in dBm or a visual approximation using a series of symbols (
#
). The more symbols (
#
displayed, the stronger the signal. Real-time receiver levels are displayed within ±1 dBm accuracy. If the 
link is down and remote end data is unavailable, 
D
ATA
 N
OT
 A
VAILABLE
 displays in place of the symbols (
#
). 
Pressing (+) on this field sets the 
T
X
 P
OWER
 to full strength; pressing (-) reduces the 
T
X
 P
OWER
 to the 
minimum. 
Reducing the transmitter power of the remote TRACER 64x0 could cause the RF link to 
drop, requiring a technician to increase the transmit power by using the menu system at 
the remote site.