AT-A-GLANCE SPECIFICATIONS
Table 12 contains a list of specifications for the TRACER 6420 system.
Table 12.  At-A-Glance Specifications  
Hardware
Description
Specification
Transmitter
Output Power
+20 dBm, max
Frequency Range
5725 to 5850 MHz 
Receiver
Receive Level, 
Minimum
-88 dBm @ 8xT1
 
-91 dBm @ 4xT1
 
-94 dBm @ 2xT1
Receive Level, Maximum
-30 dBm 
Receive Level, Nominal
-55 dBm 
Frequency Plan
Plan A
Channel 
Plan
1
Tx 5.744 GHz, Rx 5.824 GHz 
2
Tx 5.747 GHz, Rx 5.827 GHz 
3
Tx 5.751 GHz, Rx 5.831 GHz 
Plan B
Channel 
Plan
1
Tx 5.824 GHz, Rx 5.744 GHz 
2
Tx 5.827 GHz, Rx 5.747 GHz 
3
Tx 5.831 GHz, Rx 5.751 GHz 
Data Encryption
Encryption Type
Symmetric Triple-DES (3DES)
User Interface
Panel
Alarm LEDs
Diagnostics
RF link diagnostics and error history, transmit and 
receive packets history
Test Points
RSSI, Ground (GND), and Test (QPSK Constellation)
Alarms
Normally Open (NO) and Normally Closed (NC)
VT100 Terminal
Menu Driven User Interface, Control of the Remote 
End, Event History
Telnet Access
Menu Driven User Interface, Control of the Remote 
End, Event History
SNMP 
Standard MIB support (T1 and Ether-like MIBs); 
Enterprise MIB support (ADTRAN TRACER)