Set Point-to-Point Direct Mode
Sets point-to-point mode that is recommended for point-to-point applications, especially
where the remote radio is mobile and may leave and re-enter the range of the base. This
mode fixes the remote handle assignment to always be 30H and improves the re-
registration process. Must be set in both base and remote radios.
Set Range Optimization (remote only)
This command applies an adjustment factor to the over-the-air timing of remotes to
compensate for the effects of propagation delay at long ranges.  The default setting of
00H is suitable for ranges of 0 to 0.8 miles (1287 m), with optimal performance at 0.1
miles (162m).  Each increment of this parameter adds 0.1 miles (162 m) to the working
range. Thus the optimal and max ranges are determined by:
optimal = 0.1mi + 0.1mi x  dx = 0.17km + 0.17km x  dx
max = 0.8mi + 0.1mi x  dx = 1.33km = 0.17km x dx
The following table presents various values of dx and the associated optimal and max ranges.
dx
setting
range:
min
optimal
max
00H
0mi/0km
0.1mi/0.2km
0.8mi/1.3km
01H
0mi/0km
0.2mi/0.3km
0.9mi/1.5km
04H
0mi/0km
0.5mi/0.8km
1.2 mi/2.0km
06H
0.1mi/0.2km
0.7mi/1.2km
1.4mi/2.3km
09H
0.4mi/0.7km
1.0mi/1.6km
1.8 mi/3.0km
13H
1.4mi/2.3km
2.0mi/3.3km
2.8mi/4.7km
31H
4.4mi/7.3km
5.0mi/8.3km
5.8 mi/9.7km
45H
6.4mi/10.7km
7.0mi/11.7km
7.8mi/13.0km
64H
9.4mi/15.7km
10.0mi/16.7km
10.8mi/18.0km
C8H
19.3mi/32.3km
20.0mi/33.3km
20.8mi/34.7km
FAH
24.4mi/40.7km
25.0mi/41.7km
25.8mi/43.0km
     
 Optimal 'dx' setting for various distances.