Murata Electronics North America 2410P Manual Do Utilizador

Página de 59
WIT2410P 
© 2000- 2008 Cirronet™ Inc 
25 
M-2410P-0000 Rev G2 
Set Point-to-Point Direct Mode 
Sets point-to-point mode that is recommended for point-to-point applications, especially 
where the remote radio is mobile and may leave and re-enter the range of the base. This 
mode fixes the remote handle assignment to always be 30H and improves the re-
registration process. Must be set in both base and remote radios. 
 
Set Range Optimization (remote only) 
This command applies an adjustment factor to the over-the-air timing of remotes to 
compensate for the effects of propagation delay at long ranges.  The default setting of 
00H is suitable for ranges of 0 to 0.8 miles (1287 m), with optimal performance at 0.1 
miles (162m).  Each increment of this parameter adds 0.1 miles (162 m) to the working 
range. Thus the optimal and max ranges are determined by: 
 
 
optimal = 0.1mi + 0.1mi x dx = 0.17km + 0.17km x dx 
 
max = 0.8mi + 0.1mi x dx = 1.33km = 0.17km x dx 
 
The following table presents various values of dx and the associated optimal and max ranges. 
 
dx 
setting 
range: 
min
 
  
optimal 
 
max 
00H 
0mi/0km 
0.1mi/0.2km 
0.8mi/1.3km 
01H 
0mi/0km 
0.2mi/0.3km 
0.9mi/1.5km 
04H 
0mi/0km 
0.5mi/0.8km 
1.2 mi/2.0km 
06H 
0.1mi/0.2km 
0.7mi/1.2km 
1.4mi/2.3km 
09H 
0.4mi/0.7km 
1.0mi/1.6km 
1.8 mi/3.0km 
13H 
1.4mi/2.3km 
2.0mi/3.3km 
2.8mi/4.7km 
31H 
4.4mi/7.3km 
5.0mi/8.3km 
5.8 mi/9.7km 
45H 
6.4mi/10.7km 
7.0mi/11.7km 
7.8mi/13.0km 
64H 
9.4mi/15.7km 
10.0mi/16.7km 
10.8mi/18.0km 
C8H 
19.3mi/32.3km  20.0mi/33.3km 
20.8mi/34.7km 
FAH 
24.4mi/40.7km  25.0mi/41.7km 
25.8mi/43.0km 
     
 Optimal 'dx' setting for various distances.