Murata Electronics North America 2410P Manual Do Utilizador

Página de 59
WIT2410P 
© 2000- 2008 Cirronet™ Inc 
26 
M-2410P-0000 Rev G2 
5.3.  Protocol Commands 
 
These commands can be used to tune the transceiver for optimum transmission of data 
across the RF link.  For most applications, the default values are adequate. 
 
 
Command 
 
Description 
pe[?|0-B] 
Set Alternative Frequency Band 
 
0
 = USA operation.  (~2400 – 2472MHz) (default) 
 
1
 = ~2448 – 2474MHz, avoids 11b channels 1 – 6 & 14 
 
2
 = Spain (~2448 – 2474MHz), avoids 11b channels 1 – 6 & 14 
 
3
 = Japan (~2471 – 2497MHz), avoids 11b channels 1 - 10 
 
4 = Canada (~2452 – 2477MHz), avoids 11b channels 1 – 6 & 14 
 
5 = ~2400 – 2425MHz, avoids 11b channels 6 - 14 
 
6 = ~2409 – 2435MHz, avoids 11b channels 8 - 14 
 
7 = ~2419 – 2445MHz, avoids 11b channels 1 & 10 – 14 
 
8 = ~2430 – 2455MHz, avoids 11b channels 1, 2 & 12 – 14 
 
9 = ~2440 – 2465MHz, avoids 11b channels 1 – 4 & 14 
 
A = ~2449 – 2475MHz, avoids 11b channels 1 – 6 & 14 
 
B = ~2459 – 2485MHz, avoids 11b channels 1 – 7 
 
 
ph[?|00-fe] 
(base only) 
 
Set Hop Duration 
 
90H
 = default (=10ms) 
 
pk[?|00-d0] 
     
 
Set Minimum Data Length 
 
01
 = default 
 
pl? 
(remote only)                         
 
Get Maximum Data Length (read only) 
 
D4
 = default (=212 bytes) 
pn[?|01-3e] 
(base only) 
Set Maximum Number of Remotes 
 
3e = default (=62 remotes) 
 
pr[?|00-ff] 
                                   
 
Set Packet Attempts Limit 
 
10H
 = default 
 
FFH
 = Infinite retry (RF flow control point-to-point only) 
 
pt[?|00-ff] 
 
 
Set Data Transmit Delay 
 
00H
 = default    
pv[?|0|1] 
 
(base only) 
Set Slot Assignment Mode 
 
= default (dynamic slot assignment) 
 
1
 = static slot assignment 
pw[?|00-34] 
(base only) 
Set Base Slot Size 
 
08H
 = default (=32 bytes) 
px[?|0|1] 
Set ARQ mode.   
 
0
  = ARQ enabled (default) 
 
1
  = ARQ disabled (redundant transmission) 
Note: Incorrect setting of these parameters may result in reduced throughput or loss of data packets.   
 
 
Set Alternative Frequency Band 
When set to 1, limits the operating RF channel set to the 2448 to 2473MHz frequency 
band for compliance with French regulatory standards.  When set to 2, sets appropriate 
operation for Spain.  When set to 3, sets appropriate operation for Japan.  This setting