Murata Electronics North America 2492 Manual Do Utilizador

Página de 58
WIT2492 
 2000- 2007 Cirronet  
40
M-2492-0000 Rev G1 
 
 
 
7.3. WinCom Tools 
 
There are seven selections under the Tools menu. The first, Obey CTS is useful when just 
a three wire connection is made between the radio and the computer. Some PCs let the 
CTS input line float. If CTS is not asserted, the PC COM port will not send data. 
Note: Unchecking this selection will have the PC COM port 
ignore the state of CTS and transmit data. 
 
 
When WinCOM’s transmit mode is used, data is sent continuously until the user stops it 
by clicking on Stop or pressing F6. If the second tool, Single Transmit, is checked, 
clicking the Transmit button will send the Transmit String a single time. There is no need 
to click Stop. Clicking on the Transmit button a second time will have the string 
transmitted a second time. 
The third allows for checking of available Comm Ports and is useful for refreshing the 
list. 
 
The fourth, Transmit Tools allows for testing of the Transparent, WIT2492/WIT910 or 
WIT2411 settings. Parameters related to how the transmission will take place can be set 
including Handle, Transmit Period, whether or not a Sequence Number should be added, 
if the Transmission will be continuous or one time, if the data should be sent in Hex 
Format and whether or not data can be received. Data is entered into the Data field, then 
Data Size can be set and clicking Fill loads the data into the Transmit Field.