Murata Electronics North America 2492 Manual Do Utilizador
WIT2492
2000- 2007 Cirronet
42
M-2492-0000 Rev G1
7.4. Script Commands
cp <arg>
Selects the COM port to use
br <arg>
Selects the baud rate to use
do Asserts
DTR
df De-asserts
DTR
ro Asserts
RTS
rf De-asserts
RTS
cm
Sends configuration escape sequence
oo Obey
CTS/RTS
of Do
not
obey
CTS/RTS
sc <cmd(arg)>
Send WIT910 format configuration command
wt <arg>
Pause for arg milliseconds
An example script file is shown below:
br 115200
df
wt 200
do
wt 200
cm
wt 200
sc m!
df
wt 200
do
wt 200
cm
wt 200
sc m!
This script file sets the baud rate of the PC COM that WinCOM is using to 115,200 kbps,
de-asserts DTR, waits 200 milliseconds, asserts DTR, waits 200 milliseconds, sends the
configuration mode escape sequence, waits 200 milliseconds and then sends the m!
command to the radio. What this script file does is set the PC COM port baud rate to
115.2 kbps, puts the radio in config mode and the issues the command to display all of
the radio parameters that have been changed from factory default. Note that this script
file leaves the radio in config mode. Cycling power or toggling DTR will return the radio
to data mode.
de-asserts DTR, waits 200 milliseconds, asserts DTR, waits 200 milliseconds, sends the
configuration mode escape sequence, waits 200 milliseconds and then sends the m!
command to the radio. What this script file does is set the PC COM port baud rate to
115.2 kbps, puts the radio in config mode and the issues the command to display all of
the radio parameters that have been changed from factory default. Note that this script
file leaves the radio in config mode. Cycling power or toggling DTR will return the radio
to data mode.
WinCOM prompts you to select the desired .wcr file. Opening the script file causes it to
executed immediately.
executed immediately.