Murata Electronics North America 2492 Manual Do Utilizador

Página de 58
WIT2492 
 2000- 2007 Cirronet  
44
M-2492-0000 Rev G1 
 
 
 
7.5. Demonstration Procedure 
The procedure below provides a quick demonstration of the WIT241x. 
 
1.  Attach a transceiver to each computer, preferably between 5' and 30' apart for 
convenience. 
 
2.  Start WinCOM running on both computers   If you prefer, almost any other serial 
communications program such as Procomm or QModem set for 9600 bps will 
also work. 
 
3.  Turn the radios on and use the function keys to set DTR and RTS to 1  (if you are 
using a terminal program other than COM24, these are typically set 
automatically).  The radio should respond by setting both DSR and CTS to 1, and 
transmit a short sign-on message including the firmware version and whether the 
unit is configured as a base or remote.  Watch the states of the hardware control 
lines on the status bar as you do this.  The DCD indicator should be lit on the base 
station.  After a few seconds, the remote unit will acquire the base station's signal 
and also assert its DCD signal. 
 
4.  Access modem control mode for each unit.  To access modem control mode, use 
the F1 key to toggle DTR to 0 and back to 1 and then press the F3 key, which 
sends the ":wit2400" escape sequence.  If you are not using COM24, simply turn 
the radio off and back on and then type ":wit2400" (must be lower case, no 
backspace characters).  The transceiver should echo back “
>
” to indicate that you 
have entered modem control mode. 
Check the remote unit's hopping pattern by 
entering "wn?" at the prompt.  The remote should respond with "0", the default 
setting.  Check that the base station's hopping pattern matches this by entering 
"wn?" at the base station. 
 
5.  Exit control mode by entering "z>".  Do this for both radios.  At this point, you 
should be able to type characters into either radio and see them appear at the other 
side.  If you are using WinCOM, you can press the F6 key to transmit a repeating 
test pattern. 
 
6.  For a range test, disconnect the remote station from the computer and power 
supply. The DCD indicator should remain lit as long as the base station is in 
range.. 
 
7.  Exit COM24 by pressing the ESC key.