Canadian Department of Communications Industry
Notice - IC: 4492A-DM1810A
This apparatus complies with Health Canada’s Safety
Code 6 / IC RSS 210.
To prevent radio interference to the licensed service,
this device is intended to be operated indoors and
away from windows to provide maximum shielding.
Equipment (or its transmit antenna) that is installed
outdoors may be subject to licensing.
ICES-003
This digital apparatus does not exceed the Class B
limits for radio noise emissions from digital apparatus
as set out in the radio interference regulations of In-
dustry Canada.
Le present appareil numerique n’emet pas de bruits
radioelectriques depassant les limites applicables aux
appareils numeriques de Classe B prescrites dans le
reglement sur le brouillage radioelectrique edicte par
Industrie Canada.
3
Pin
Name
Description
J1-1
GND
This pad is a signal and power supply ground.
J1-2
VIN
This is the power supply input pad. The allowed input voltage range is 2.6 to 10 V.
J1-3
VOUT
VOUT tracks 50 to 100 mV below VIN when VIN is in the range of 2.6 to 3.1 V. When VIN is in the range of 3.1
to 10 V, VOUT is regulated at 3.0 Vdc. Up to 10 mA can be supplied from this pad for powering external circuits
such as thermistor-resistor networks. External circuitry must not impress more than 10 mV
p-p
ripple on the regu-
lated output voltage.
J1-4
BIND
This pad is connected to a logic input on the microcontroller, and is configured with a weak pull-up. When this
pin is momentarily grounded to J1-1 or J1-10, the module is placed into the bind mode, allowing this module to
be associated with other modules to form a network.
J1-5
-
This pad is unused in base station operation. Leave this pad electrically unconnected.
J1-6
-
This pad is unused in base station operation. Leave this pad electrically unconnected.
J1-7
-
This pad is unused in base station operation. Leave this pad electrically unconnected.
J1-8
SERIAL RX
This pad is connected to the module’s serial data input (USART). Data to this pin is received at 9.6 kb/s, using
8 data bits, no parity, and one stop bit. The input voltage range on this pad is 0 to VOUT. Applying a voltage
outside of this range may damage the module.
J1-9
SERIAL TX
This pad is connected to the module’s serial data output (USART) through a 1 kilohm resistor, which provides
short-circuit protection. Data from this pad is sent at 9.6 kb/s, using 8 data bits, no parity, and one stop bit.
J1-10
GND
This pad is a signal and power supply ground.
J3-1
GND
This pad is a ground for the antenna port.
J3-2
ANT
This pad is the antenna port.
J3-3
GND
This pad is a ground for the antenna port.
J4-1
D1
This pad is the LED 1 signal.
J4-2
D2
This pad is the LED 2 signal.
CAUTION: Electrostatic Sensitive Device. Observe precautions when handling.
DM1810-916MB I/O Pad Descriptions