3.2 Module Interface 
Electrical connections to the DNT900C are made through the I/O pads and through the I/O pins on the 
DNT900P. The hardware I/O functions are detailed in the table below: 
Pad 
Name 
Description 
RSVD 
Reserved pad. Leave unconnected. 
RSVD 
Reserved pad. Leave unconnected. 
ADC_REF 
ADC supply and external full scale reference voltage input. Voltage range is 2.4 to 3.3 Vdc. 
Connect pad 34 to this input to reference the ADC full scale reading to the module’s 3.3 V 
regulated supply. 
RSVD 
Reserved pad. Leave unconnected. 
GPIO0 
Configurable digital I/O port 0. When configured as an input, an internal pull-up resistor can be 
selected and interrupt from sleep can be invoked. When configured as an output, the power-on 
state is also configurable. 
GPIO1 
Configurable digital I/O port 1. Same configuration options as GPIO0. 
GPIO2 
Configurable digital I/O port 2. Same configuration options as GPIO0. 
GPIO3 
Configurable digital I/O port 3. Same configuration options as GPIO0. 
PWM0 
Pulse-width modulated output 0 with internal low-pass filter. Filter is 1
st
 order, 159 Hz 3 dB BW. 
10 
PWM1 
Pulse-width modulated output 1 with internal low-pass filter. Filter is 1
st
 order, 159 Hz 3 dB BW. 
11 
SLEEP 
Default functionality is active high module sleep input. When switched low after sleep, the 
module executes a power-on reset. 
12 
ADC0 
10-bit ADC input 0. Full scale reading is referenced to the ADC_REF input. 
13 
ADC1 
10-bit ADC input 1. Full scale reading is referenced to the ADC_REF input. 
14 
ADC2 
10-bit ADC input 2. Full scale reading is referenced to the ADC_REF input. 
15 
RSVD 
Reserved pad. Leave unconnected. 
16 
DIAG_TX 
Diagnostic output (for factory use). 
17 
DIAG_RX 
Diagnostic input (for factory use). 
18 
/CFG 
Protocol selection input. Leave unconnected when using software commands to select trans- 
parent/protocol mode (default is transparent mode). Logic low selects protocol mode, logic high 
selects transparent mode. 
19 
VCC 
Power supply input, +3.3 to +5.5 Vdc. 
20 
GND 
Power supply and signal ground. Connect to the host circuit board ground. 
21 
GND 
Power supply and signal ground. Connect to the host circuit board ground. 
22 
GPIO4 
Configurable digital I/O port 4. When configured as an input, an internal pull-up resistor can be 
selected. When configured as an output, the power-on state is configurable. 
23 
GPIO5 
Configurable digital I/O port 5. Same configuration options as GPIO4. 
24 
RSVD 
Reserved pad. Leave unconnected. 
25 
ACT 
Data activity output, logic high when data is being transmitted or received. 
26 
/DCD 
Default functionality is data carrier detect output, which provides a logic low on a remote when 
the module is locked to FHSS hopping pattern and logic low on a base station when at least 
one remote is connected to it.