Pad 
Name 
Description 
27 
RSVD 
Reserved pad. Leave unconnected. 
28 
RSVD 
Reserved pad. Leave unconnected. 
29 
RSVD 
Reserved pad. Leave unconnected. 
30 
/UART0 _ RTS 
Default functionality is UART flow control input for the module’s host. A logic low allows data 
flow from the module to the host; a logic high blocks data flow from the module to the host. 
31 
UART0_RXD  UART received data output to host from module. 
32 
UART0_TXD  UART host data input to be transmitted by module. 
33 
/UART0 _ CTS 
UART flow control output from the module to the host. A logic low should allow data flow 
from the host; a logic high should block data flow from the host. 
34 
VMOD 
Module’s +3.3 V regulated supply output. Connect to pad 3 to support 3.3 V full scale and/or 
ratiometric ADC readings, etc. Current drain on this output should be no greater than 5 
mA. 
35 
RSVD 
Reserved pad. Leave unconnected. 
36 
RSVD 
Reserved pad. Leave unconnected. 
37 
RSVD 
Reserved pad. Leave unconnected. 
38 
RSVD 
Reserved pad. Leave unconnected. 
39 
/RESET 
Active low module hardware reset. 
40 
RSVD 
Reserved pad. Leave unconnected. 
41 
GND 
RF ground (DNT900CC only). Connect to the host circuit board ground plane. 
42 
RFIO 
Alternate RF port to the U.FL connector (DNT900C only). The antenna can be connected to this 
port  with  a  50  ohm  stripline  or  coaxial  cable.  Leave  unconnected  when  using  the  U.FL 
connector. 
43 
GND 
RF ground (DNT900C only). Connect to the host circuit board ground plane. 
 
Table 3.2.1 
3.3 Input Voltages 
DNT900 radio modules can operated from an unregulated DC input (Pad/Pin 19) in the range of 3.3 
(trough) to 5.5 V (peak) with a maximum ripple of 5% over the temperature range of -40 to 85 
o
C. Apply-
ing AC, reverse DC, or a DC voltage outside the range given above can cause damage and/or create a 
fire and safety hazard. Further, care must be taken so logic inputs applied to the radio stay within the 
voltage range of 0 to 3.3 V. Signals applied to the analog inputs must be in the range of 0 to ADC_REF 
(Pad/Pin 3). Applying a voltage to a logic or analog input outside of its operating range can damage the 
DNT900 module. 
3.4 ESD and Transient Protection 
The DNT900C and DNT900P circuit boards are electrostatic discharge (ESD) sensitive. ESD precautions 
must be observed when handling and installing these components. Installations must be protected from 
electrical transients on the power supply and I/O lines. This is especially important in outdoor installations, 
and/or where connections are made to sensors with long leads. Inadequate transient protection can result 
in damage and/or create a fire and safety hazard.