Murata Electronics North America HN1010 Manual Do Utilizador

Página de 58
 
 
Configuring the Network 
M-2410-0010, Rev. - 
HopNet Family of Products 
35 
Status Commands 
These commands deal with general interface aspects of the operation of the HopNet. 
   
Command 
 
Description 
 
zb[?|0|1]  
 
Banner Display Disable 
 
0 = disabled 
 
1 = enabled   (default) 
 
zc[?|0..2]  
 
Set Escape Sequence Mode 
 
0 = disabled 
 
1 = once after reset   (default) 
 
2 = unlimited times 
zh? 
Read factory serial number high byte. 
zm? 
Read factory serial number middle byte. 
zl? 
Read factory serial number low byte. 
zp[?|0-5]                   
 
           (base only) 
Set the duty cycle at which the modem will wake up to send and 
receive data.  Duty cycle equals 1/2
N
 where the argument of the 
command equals N. 
zq[?|0|1] 
 
(remote only) 
Low Power Acquisition Mode Enable 
 
0 = Disabled (default) 
 
1 = Enabled 
 
z> 
 
Exit Modem Control Mode 
Banner Display Disable
 
Enables or disables display of the banner string and revision code automatically at 
power-up.  May be disabled to avoid being mistaken for data by the host. 
Set Escape Sequence Mode 
 
Enables or disables the ability to use the in-data-stream escape sequence method of 
accessing Control Mode by transmitting the string ":wit2410".  When this mode is set 
to 1, the escape sequence only works immediately after reset (this is the default).  
When set to 2, the escape sequence may be used at any time in the data stream when 
preceded by a pause of 20 ms.  For backwards compatibility with the WIT2400, the 
string ":wit2400" is also accepted for entering Control Mode.  Note that the escape 
sequence must be interpreted as data by the radio until the last character is received, 
and as such will be transmitted to a receiving radio station.