Configuring the Network 
M-2410-0010, Rev. - 
HopNet Family of Products 
37 
Memory Commands 
The user is able to store a configuration in nonvolatile memory, which is loaded 
during the initialization period every time the radio is powered up. Note that changes 
to the serial port baud rate- from recalling the factory defaults or recalling memory -
will not take effect until DTR is toggled or power to the radio is cycled.
 
 
Command 
 
Description 
 
m0 
 
Recall Factory Defaults 
 
m< 
 
Recall Memory 
 
m> 
 
Store Memory 
Recall Factory Defaults 
 
Resets the HopNet to its factory default state.  This is useful for testing purposes or if 
there is a problem in operation of the system and the configuration is suspect.  Use 
the Store Memory command afterwards if you wish the factory default settings to be 
remembered the next time you cycle power or reset the radio. 
Recall Memory 
 
Useful for restoring the power-on settings after experimenting with temporary 
changes to data rate, protocol or network parameters, etc.   
Store Memory 
 
This command is necessary after any command to change the data rate, transceiver 