Murata Electronics North America SEM2410 Manual Do Utilizador

Página de 23
 
 2000, 2001  Cirronet
 Incorporated 
14 022101 
Radio Modem Configuration 
The “radio” command provides access to several sub-commands that are useful in 
configuring the WIT2410 in the SEM.  The format for the radio commands is 
radio 
{A|B} <sub-cmd> [<sub-cmd-args>]
, where the 
{A|B}
 is either of the letters ‘A’ or 
‘B’ used to specify to which radio the sub-command should be applied.  The SEM uses 
only the radio ‘A’ designation; the ‘B’ designation is for future use. The command 
radio 
{A|B} banner
 can be used to display the banner from the radio.  This is useful in 
determining the unique ID of the radio and the version of firmware running in the radio.   
Radio Commands 
The radios in the SEM devices are set with factory defaults which should be sufficient for 
most applications. For other applications, the following radio commands can be used to 
fine tune the performance of the SEM. 
Command Description 
help 
Displays command list 
banner 
Displays power on banner for the radio in the SEM  
defaults 
Resets the radio parameters to the factory shipped values
 
maxremotes [ 
 0..5] 
Displays value currently in use 
Sets the maximum number of subscribers the SEM  will allow to 
register.  
 Default 
network [ 
 0..63] 
Displays current SEM network number 
Sets the network number for the SEM 
 Default 
param <rcmd> 
 [arg0,arg1…] 
Sets other radio parameters. Should not be used unless instructed to by 
Cirronet Technical Support 
radio a 
show 
Displays radio parameters that have been modified from factory 
settings 
 
 
help 
Displays list of sub-commands under the radio command. 
 
banner 
Displays the power on banner of the radio inside the SEM. 
 
defaults 
Replaces any modified parameters with the factory default values.  
 
maxremotes  Sets a limit to the number of remotes SEMS that a master SEM can have 
registered simultaneously. The default is 5 but the parameter can range 
from 1 to 5. If more than maxremotes remote SEMs attempt to connect to 
the access point, they will be denied.