8.4.3  UART Timing Values 
 
Variable 
Meaning 
Min 
Max 
Units 
t
RX_BAUD
 
Deviation from baud rate 
-2 
+2 
t
RX_STOP
 
Number of stop bits 
 
bit period 
t
TX_BAUD
 
Deviation from baud rate 
-1 
+1 
t
TX_STOP
 
Number of stop bits 
 
bit period 
t
SP_CTS to MT_RTS
 
Assertion of /SP_CTS to negation of /MT_RTS 
10 
ms 
t
MT_RTS to SP_CTS
 
Assertion of /MT_RTS to assertion of /SP_CTS 
 
500 
ms 
t
SP_CTS to TX
 
Assertion of /SP_CTS to start of byte 
10 
ms 
t
TX to SP_CTS
 
Start of byte to negation of /SP_CTS 
 
bit period 
t
SP_CTS ack PW
  
Negation pulse width of /SP_CTS 
500 
 
ns 
t
diag_ack_timeout
 
The XDM2140 responds to all requests within this time. 
 
125 
ms 
t
min_strobe_length
 
The minimum length of the strobe signals, /TIME and /SP_CTS 
500 
 
ns 
t
interbyte_timeout
 
Falling edge of TX to falling edge of /SP_CTS (Mode 3 only) 
 
ms 
t
interpacket_delay
 
The sender of an HDLC packet must wait at least this amount of time 
before sending another packet 
20 
 
ms 
t
ack_delay
 
The max time delay between the /MT-RTS and the receiver’s 
acknowledge, /SP_CTS 
500 
ms 
t
time_ack_timeout
 
The XDM2140 responds to all /TIME pin activation requests within this 
time 
 
100 
ms 
 
Table 16 
 
Power-on Sequence 
TX
HIGH-Z
HIGH-Z
HIGH-Z
t
boot_delay
RST
MT_RTS
MT_CTS
 
Figure 5