Murata Electronics North America XDM2140 Manual Do Utilizador
Response 0x09 Format Details
Message Byte
Description
Data Type
Value
1
Command type
unsigned char
0x09
2
Payload length
unsigned char
0x00
3
Flags
unsigned char
0x01 (response packet)
4
Response code
unsigned char
0x00 (OK)
Table 29
9.3 Get/Set Command Parameters
This section specifies the parameters that may be used with the Get and Set Commands. Table 35
provides an overview of these parameters.
provides an overview of these parameters.
Get/Set Command Parameters
Parameter Type
Set Parameter
Get Parameter
Description
0x01
X
Set the XDM2140’s network ID
0x02
X
Get the XDM2140’s current network connection state
0x03
X
Get the network frame length
0x04
X
Set the network join key on the XDM2140
0x05
X
Get the network time and XDM2140 state information
0x06
Reserved
0x07
X
Get the XDM2140’s properties
0x08
X
X
Set/get the power amplifier mode
0x09
Reserved
0x0A
X
Get the XDM2140’s charge consumption
0x0B
X
X
Set/get the XDM2140 power source value
0x0C
X
X
Put XDM2140 into RF testing mode
Table 30
All requests have the following structure.
Request Structure for Parameter Data Packets
Command Type
Parameter Type
Data (Optional)
1 byte
1 byte
Up to 33 bytes
Table 31
All replies have the following structure.
Reply Structure for Parameter Data Packets
Command Type
Parameter Type
Error Code
Data Length
Data (Optional)
1 byte
1 byte
1 byte
1 byte
Up to 31 bytes
Table 32
Command Types, Parameter types, and error codes are discussed in the following sections. Data length
is the number of bytes of following data, set to 0 in case of non-zero error code.