Wake Duration - This setting controls the length of time a module will remain awake when it
wakes due to Check Parent timer. The default setting is 100 milliseconds. The minimum length
of time is 30 milliseconds and the maximum duration is 65.5 seconds.
wakes due to Check Parent timer. The default setting is 100 milliseconds. The minimum length
of time is 30 milliseconds and the maximum duration is 65.5 seconds.
5.10 Serial Comm
Click on the Serial Com button to bring up the text messaging window as shown below.
There are four fields/windows in this box: the Destination Address window top left of the box, the
Incoming Data field top right of the box, the Messaging Display window in the middle of the box;
and the Text to Send window at the bottom of the box. The Clear button allows you to clear the
contents of the Messaging Display window.
The Destination Address window is used to select the ZigBee device to which to send a text
string. The drop down menu will display the Long Network Addresses of the devices that were
found to be part of the network through the Discover command. The Long Network Address is
the two bytes displayed in the Network Address field preceded by
Incoming Data field top right of the box, the Messaging Display window in the middle of the box;
and the Text to Send window at the bottom of the box. The Clear button allows you to clear the
contents of the Messaging Display window.
The Destination Address window is used to select the ZigBee device to which to send a text
string. The drop down menu will display the Long Network Addresses of the devices that were
found to be part of the network through the Discover command. The Long Network Address is
the two bytes displayed in the Network Address field preceded by
80:00:00:00:00:00
.
Example: If the Network Address is
0x0001
, the Long Network Address will be
80:00:00:00:00:00:00:01.
Select the Long Network Address of the desired device.
ZigBee uses a packet format to send data. Rather than waiting for a long pause between
keystrokes to determine the end of the data, ZBDemo requires the text be entered in the Text to
Send window and the Send button clicked. ZBDemo can send a maximum of 68 bytes per
packet thus the maximum number of characters that can be sent in a single packet is 64. When
the String Messaging window is open, the radio information will not be refreshed.