9.5.17 Obstruction Light Installation and Wiring
The  obstruction  light  assembly  is  shipped  separately  from  the  VOR  antenna  kits  and  it  is  necessary  to  attach  the 
obstruction light to the top of the VOR Monitor or DME antenna; and the wiring that extends from the antenna must 
be connected to the bulb sockets. For connection of SELEX-SI DME antenna obstruction lights please refer to the 
DME manual.     
 
a. 
Remove lens and bulbs. 
b. 
Remove the hole cap at the top of the DME antenna and fish out the AC wires using stiff wire bent into a 
hook. 
c. 
Route the three wire AC cable from the DME antenna through the required pipe adapters and into the bulb 
sockets. 
d. 
Thread  the  obstruction  light  assembly  into  the  antenna.    Use  thread  tape  on  all  pipe  threads  to  insure  a 
water tight fit. 
e. 
Connect the three AC wires from the antenna to the bulb sockets, as shown in 
and
 
f. 
Install the lighting rod (if provided) to the obstruction light nipple if provided. 
g. 
Verify the obstruction light bulbs match the site AC voltage rating then install the bulbs and lens. 
h. 
After  installing  obstruction  light,  connect  remaining  obstruction  light  power  wires  to  VOR  cabinet  and 
shelter circuit breaker box as shown in 
 and 
.
Figure 9-5  VOR Obstruction Light Interconnect Diagram with Photo Sensor