HID Global Corporation 609XA Manual Do Utilizador

Página de 4
Installation Guide   
 
 
iCLASS Reader Models bio500, RWKL550 & RWKLB575 
          
 
 
 
 
An 
ASSA 
ABLOY 
Group 
company 
                    
ASSA ABLOY
 
_____________________________________________________________________________________________________ 
HID Corporation  9292 Jeronimo Road   Irvine, CA 92618-1905 USA TEL (949) 598-1600  (800) 237-7769  FAX (949) 598-1690 
Web page - www.hidcorp.com e-mail – tech@hidcorp.com 
 iCLASS Biometric/LCD keypad Reader Install Manual 6096-901 Rev A.2 
Page 1 of 4 
PARTS INCLUDED 
SPECIFICATIONS 
• 1 
- iCLASS LCD Keypad Reader with optional Bio 
• 
Reader Input Voltage:        9-12 VDC  
• 
1 - Installation Manual 
• 
Current Range:                  350 mA standby / 520 mA peak. 
• 
2 - #6-32 x .25” x  Phillips machine screws 
• 
Cable distance to Host:     50 ft (15 m) max – RS-232. 
• 
3 - #6-32 x .375” Phillips self-tapping machine screws  
  4000 ft (1216 m) max – RS-485 
• 
2 - #6 x 1.5” Phillips sheet metal screws  
16 Gauge Wire  500 ft (152 m) max – Wiegand 
• 
2 - #6-32 x .375” Spanner security screws  
20 Gauge Wire  200 ft (60 m) max – Wiegand 
• 
1 - 10 Position Phoenix Plug 
 
 
• 
1 - 8 Position Phoenix Plug 
• 
Op. Temperature:            32 °F - +113 °F (0 °C – +45 °C) 
• 
1- Foam Gasket 
• 
Open collector output: 
Sink – 40 mA, source – 1 mA. 
 
 
 
Recommended: 
 
 
• 
Up to 10 wire splices 
• 
Security Tool (for security screw) HID 04-0001-03 
 
Standards:
 
 
• 
Cable, 9 conductor, 22 AWG, shielded (Wiegand) 
• 
Linear 12 VDC, 1 A Power Supply 
• 
Read/Write capability in ISO 15693 mode with HID iCLASS 
credentials. 
• 
Cable , 6 conductor, 22 AWG, shielded (Serial) 
• 
Metal or plastic junction box 
• 
Read/Write capability in ISO 14443B mode with HID iCLASS 
16KS. 
• 
Magnetic Tamper switch - Ademco 945T, Sentrol 
1038T, GRI 100T or 110T or Aleph DC-2531 
• 
Read capability of CSN/UID in ISO 14443A mode with HID 
Mifare and other 3
rd
 party Mifare credentials. 
 
Description 
                     
                      
 
        RWKLB575                                          RWKL550                                                bio500 
  
The bioCLASS range is intended for indoor use only and should never be mounted on an exterior wall.
 
 
INSTALLATION  
 
1- Install Tamper Switch 
An internal magnet provides tamper indication when used with a magnetic reed switch connected to an external alarm system.  
Locate Switch behind the left side of the mounting plate, centered between the mounting holes. 
                               
 
        
 
 
 
 
Electrical Back Box 
Wall Surface