PARTS INCLUDED
SPECIFICATIONS
• 1
- iCLASS LCD Keypad Reader with optional Bio
•
Reader Input Voltage: 9-12 VDC
•
1 - Installation Manual
•
Current Range: 350 mA standby / 520 mA peak.
•
2 - #6-32 x .25” x Phillips machine screws
•
Cable distance to Host: 50 ft (15 m) max – RS-232.
•
3 - #6-32 x .375” Phillips self-tapping machine screws
4000 ft (1216 m) max – RS-485
•
2 - #6 x 1.5” Phillips sheet metal screws
16 Gauge Wire 500 ft (152 m) max – Wiegand
•
2 - #6-32 x .375” Spanner security screws
20 Gauge Wire 200 ft (60 m) max – Wiegand
•
1 - 10 Position Phoenix Plug
•
1 - 8 Position Phoenix Plug
•
Op. Temperature: 32 °F - +113 °F (0 °C – +45 °C)
•
1- Foam Gasket
•
Open collector output:
Sink – 40 mA, source – 1 mA.
Recommended:
•
Up to 10 wire splices
•
Security Tool (for security screw) HID 04-0001-03
Standards:
•
Cable, 9 conductor, 22 AWG, shielded (Wiegand)
•
Linear 12 VDC, 1 A Power Supply
•
Read/Write capability in ISO 15693 mode with HID iCLASS
credentials.
credentials.
•
Cable , 6 conductor, 22 AWG, shielded (Serial)
•
Metal or plastic junction box
•
Read/Write capability in ISO 14443B mode with HID iCLASS
16KS.
16KS.
•
Magnetic Tamper switch - Ademco 945T, Sentrol
1038T, GRI 100T or 110T or Aleph DC-2531
1038T, GRI 100T or 110T or Aleph DC-2531
•
Read capability of CSN/UID in ISO 14443A mode with HID
Mifare and other 3
Mifare and other 3
rd
party Mifare credentials.
Description
RWKLB575 RWKL550 bio500
The bioCLASS range is intended for indoor use only and should never be mounted on an exterior wall.
The bioCLASS range is intended for indoor use only and should never be mounted on an exterior wall.
INSTALLATION
1- Install Tamper Switch
An internal magnet provides tamper indication when used with a magnetic reed switch connected to an external alarm system.
Locate Switch behind the left side of the mounting plate, centered between the mounting holes.
Locate Switch behind the left side of the mounting plate, centered between the mounting holes.
Electrical Back Box
Wall Surface