Trimble Inc. 8262090 Manual Do Utilizador

Página de 48
5
     Troubleshooting
4 0
     SNRx10 Radio Modem User’s Guide
5.1
System troubleshooting techniques
5.1.1
General troubleshooting
Check these items when troubleshooting:
Are all the devices on the system receiving power? Use the information in 5.2 
Visual status indicators, page 43, to quic
kly check the power status of the rover 
radio.
Are all the radios in the system communicating? Use the information in 5.2 
Visual status indicators, page 43
, to make sure the rover radio is synchronized 
with the base radio and receiving data.
Are all cable connections secure and undamaged?
What were the steps that led to the problem occurring?
Can the problem be repeated?
5.1.2
Rover radio troubleshooting
Complete the following steps to check the state of the rover radio:
1.
Follow the procedure in 5.3 Retrieve radio diagnostic information, page 44, to 
access the radio diagnostics. Check the following items:
Does the rover radio have the correct firmware version loaded? If not, 
contact your Trimble dealer to get the latest firmware load.
Is the country setting correct? If not, and you are using a 2400 MHz 
modules, use the procedure in 3.3 Configure radio, page 20, to set the 
correct country. Otherwise, contact your Trimble dealer.
Is the network setting correct? If not, use the procedure in 3.3 Configure 
radio, page 20
, to set the correct network number.
For 900 MHz modules running the Easy IP protocol, is the radio mode set 
to “Rover”? If not, use the procedure in 3.3 Configure radio, page 20, to 
set the module to “Rover”.
Are the serial port settings correct for your on-machine system? If not, use 
the procedure in 3.4 Configure ports, page 25, to enter the correct settings.
For 900 MHz modules running the Kea 2-way protocol, is the MAC 
address set correctly? If not, use the procedure in 3.3 Configure radio, 
page 20, to se
t the correct MAC address.
Is the protocol set correctly? If not, use the procedure in 3.7 Change radio 
protocol, page 30
, to set the correct protocol.
DRAFT