Hughes Network Systems 38HL-001 Manual Do Utilizador
1027145 – 0001 Revision D
7–4 Commissioning HTs
Hub installation
Startup diagnostics (SUDS) begin when the CCM is first powered
up. SUDS test the CCM’s components individually
up. SUDS test the CCM’s components individually
1.
Apply power to the IDU / CCM, and observe the SUDS
sequence on the LCD:
sequence on the LCD:
For test identification details, see chapter 6, section 6.9.
SUDS Timer Test
SUDS WDT Test
SUDS PCI Test
SUDS SDPRAM Test
SUDS Ser 1 Test
SUDS Ser 2 Test
SUDS LAN ID Test
SUDS CPU Reg OK
SUDS DRAM OK
SUDS DRAM OK
If all diagnostics complete successfully, the SUDS
sequence ends with a
sequence ends with a
SUDS Completed
message, as
shown below. If a test fails, the specific test that fails is
shown with a
shown with a
FAILED
message, as shown below.
SUDS Completed
SUDS Ser 2 Test
FAILED
FAILED
or
The LCD remains inactive unless you power the CCM off,
then on. This restarts SUDS.
then on. This restarts SUDS.
If any CCM component fails, replace the CCM.
Startup diagnostics
(SUDS) sequence