Itron Inc. 24GZR Manual Do Utilizador
Chapter 7 Sensus Sonix Meters
80
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
To program the 2.4GZ OpenWay Remote Mount Gas Module
1. Program the meter drive rate into the 2.4GZ Remote Mount Gas Module using the
FC200 and Belt Clip Radio. Programming parameters are based on the configuration
file loaded into the FC200.
file loaded into the FC200.
During programming, the 2.4GZ Remote Mount Gas Module is set to the nearest 100
cubic feet with the last two digits (tens and units) programmed as zeros (0). After
programming is complete, the 2.4GZ Remote Mount Gas Module reads to the nearest
cubic foot.
cubic feet with the last two digits (tens and units) programmed as zeros (0). After
programming is complete, the 2.4GZ Remote Mount Gas Module reads to the nearest
cubic foot.
2. The 2.4GZ Remote Mount Gas Module cover design includes two ridges (1) and a
stop (2) to ensure the magnet is placed in the correct location to wake-up the module.
3. Place the magnet under the index cover with magnet face (inked Itron logo and part
number) against the bottom of the module. The arrow on the magnet must point to the
back of the module. Slide the magnet back toward the 2.4GZ Remote Mount Gas
Module back plate until it touches the stop on the bottom of the index cover. Hold the
magnet in place for 5 seconds and remove it.
back of the module. Slide the magnet back toward the 2.4GZ Remote Mount Gas
Module back plate until it touches the stop on the bottom of the index cover. Hold the
magnet in place for 5 seconds and remove it.
4. The LED will blink red three times. This signifies the 2.4GZ Remote Mount Gas
Module is searching for a programming device. Within a few seconds of locating the
FC200, the red LED will blink five more times. The FC200 will confirm
programming success or failure.
FC200, the red LED will blink five more times. The FC200 will confirm
programming success or failure.
5. Read or Check the 2.4GZ Remote Mount Gas Module using the FC200 and Belt Clip
Radio.
• If the read result is higher than the number programmed in Step 1, the 2.4GZ
Remote Mount Gas Module is counting correctly.
• If the read result is not higher than the number programmed in Step 1, replace
the 2.4GZ Remote Mount Gas Module.