AC Mains Power 
 
TDC-0971-011 CCU 100 and Repeater 100 Installation Guide 
13 
 
Proprietary and Confidential 
 
The ground lug is manufactured by AMP/Tyco Electronics (part number 320754) and is 
designed for #2 AWG solid or stranded wire (0.257-inch to 0.335-inch diameter). The lug 
must be properly crimped (never soldered) to the wire using SOLISTRAND tooling 
designed for the lug. The following figure details a proper crimp. 
 
1  Center the crimps. 
Crimps may be off-center, but not off the end of the wire 
barrel. 
2  Ensure the AWG wire size you are using matches the wire 
range or size stamped on the terminal or the splice and dies. 
3  Ensure the insulation does not enter the wire barrel. 
4  Ensure the wire is visible through the inspection hole of the 
butt splices. The wire must be flush with or extend slightly 
beyond the end of the terminal wire barrel. 
The top and bottom ends of the coaxial cable attached to the tower should be electrically 
grounded with kits for lightning protection. The antenna input connection cannot serve as 
the top ground point. For cable lengths in excess of 200 feet, ground the vertical cable run 
every 100 feet.  
 
Note  When a remote/external antenna is used, the installer must supply any 
mounting brackets and cable-management clips to secure the coaxial cable to the 
tower or structure. Consult your cable manufacturer for specifications on proper clips 
and grounding kits. Conduit clamps and tie wraps are not satisfactory methods for 
securing coaxial cables. 
For a remote 900 MHz installation with a high gain antenna, a lightning arrestor is 
supplied by Itron in the CCU 100 or Repeater 100 kit materials.  
 
AC Mains Power 
The AC mains wiring to the collector or repeater utilizes a three conductor cable. 
Terminate this cable with either a NEMA L5-15 (125V, 15A) or a NEMA L6-15 (250V, 
15A) locking plug to meet local electrical codes. The collector or repeater must be 
powered by a 90-265 VAC source defined as a maximum 15 amp branch circuit and must 
be protected by a certified branch circuit breaker. TCU 100s require a minimum 15 amp 
branch circuit breaker. Do not connect the collector or repeater to a circuit protected by a 
GFCI breaker. Size the wiring in accordance with the National Electrical Code, 
ANSI/NFPA 70, and, where applicable, the Canadian Electrical Code, Part I, CSA C22.1 
or the prevailing local code. Power wiring on the Itron-supplied power cable follows 
conventional color coding for AC wiring: green (ground), white (neutral), black (hot). 
 
 
Warning   
Securely mount the collector or repeater before connecting the dedicated AC 
mains power source. 
You must ground the collector or repeater by using either the ground wire in 
the three conductor cable, or the grounding lug on the bottom of the collector 
or repeater. For installations that use the photocell adapter, the grounding 
lug must be used to ground the CCU.