Itron Inc. CCU100T Manual Do Utilizador

Página de 64
Appendix A  Detailed CCU/Repeater Specifications 
 
50 
 CCU 100 and Repeater 100 Installation Guide 
 
Proprietary and Confidential
 
 
Antenna Specifications - 100 
Specifications for the standard (unity gain) endpoint antenna and high gain antenna are 
shown in the following table.  
 
Important  All coaxial cable connections must be properly weather-proofed per 
industry standards unless otherwise specified. This includes any connections for 
the antennas and the CCU/Repeater components. If the CCU/Repeater is installed 
indoors, only the connections located outside need to be weather-proofed.  
This device has been designed to operate with the antennas listed below that have a 
maximum gain of 8.15 dBi. Antennas not included in this list or having a gain greater than 
8.15 dBi are strictly prohibited for use with this device. The required antenna impedance is 
50 ohms. 
Specification 
Vertically polarized  High gain (8.15dBi) 
Horizontally 
polarized 
Part number 
MSE-0316-001 
MSE-0373-001 
MSE-0303-001 
Gain 
0 dBd (2.15 dBi) 
6.0 dBd (8.15 dBi) 
2 dBd (4.15dBi) 
Horizontal beamwidth 
Omnidirectional 
Omnidirectional 
Omnidirectional 
Vertical beamwidth 
-3dB minimum, =/- 40 
degrees from 
horizontal 
17 degrees 
45 degrees 
Electrical downtilt available 
0 degrees 
0 degrees 
0 degrees 
Power rating 
10W 
200W 
10W 
Impedance 
50 ohms 
50 ohms 
50 ohms 
Termination 
Type N male 
Type N female 
Type N male 
Lightning protection 
Direct ground 
Direct ground 
Direct ground 
Overall length 
radome diameter 
13 in. 
2.375 in. OD 
65 in. 
1.310 in. OD 
13 in. 
2.375 in. OD 
Mounting area length 
n/a 
~8 in.  
n/a 
Weight (without clamps) 
1 lbs.  
6 lbs.  
1 lb. 
Maximum wind speed 
160 mph 
125 mph 
160 mph 
Wind load @ rated wind speed 
n/a 
57 lbs.  
n/a 
 For the latest antenna part numbers, see the CCU 100 Ordering Guide or contact your Itron 
representative. 
To reduce potential radio interference to other users, the antenna type and its gain should be 
so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that 
permitted for successful communication.