Itron Inc. CCU100T Manual Do Utilizador

Página de 64
 
Environmental Specifications 
 
 CCU 100 and Repeater 100 Installation Guide 
 
51 
 
Proprietary and Confidential 
 
 
Environmental Specifications 
The following environmental specifications are associated with a CCU/Repeater.  
Specification 
Value 
Operating temperature 
Components  
  GPS/WAN antenna system: -33° C to 60° C 
  CCU/Repeater: -33° C to 60° C 
Storage temperature 
-40° C to 85° C 
Note  Batteries may be stored for up to two years at 25° C 
without periodic recharging. When batteries are stored at this 
temperature, an open circuit voltage audit should be conducted 
every six months.  
If the storage temperature is significantly higher than 25° C, the 
frequency of the audits must be increased.  
Humidity 
0 to 90% non-condensing  
 
 
Transmitter 
Detailed specifications for the CCU/Repeater transmitter are described in the following 
table.  
Specification 
Value 
Maximum transmit power at antenna 
27 dBm 
Frequency 
903.0 MHz to 926.8 MHz (USA) 
 
 
CCU/Repeater Power Operating Range 
  
Specification 
Value 
Voltage 
90 VAC to 265 VAC 
Frequency 
47 Hz to 63 Hz  
Average power 
10 Watts (battery trickle charge) 
Peak power 
50 Watts