Itron Inc. FNCCU4 Manual Do Utilizador

Página de 58
DRAFT
20
CCU4 Collector Field Installation and Service Guide
TDC-0359-000b 04/02
Installation Procedure Summary
5. While pressing the battery case into the battery compartment, finger-tighten the four
captive-screws until the battery case is held in place.
6. Using the flathead screwdriver, tighten the four captive-screws until the battery case is
firmly in place.
Figure 10:
Installing the Battery Pack
Supplying Power to the Collector
Once the collector is installed on the davit, you must supply it with power either from the
photoelectric sensor of the street lamp or from the secondary power wires of the wood pole.
Connecting the Collector to the Photoelectric Sensor
To power the collector when installing it on a light pole, you must remove the photoelectric
sensor, insert the power adapter end of the power cable into the socket, and replace the
photoelectric sensor.
To Connect the Collector to the Photoelectric Sensor
1. Verify power is available by using a voltmeter or AC circuit tester on the street lamp.
Note
Before removing the photoelectric sensor, note the current orientation of the sensor
window. You must restore the sensor window to the same orientation (usually north) when
finished.
If you do not have a voltmeter or AC circuit tester, verify power by placing your hand over
the photoelectric sensor window.
If power is available, the lamp lights after a brief delay.
Battery
Pack
Battery
Case