Paragon-III Technical Manual
14
3.1.6  Dual Power Supply module
The Dual Power Supply module is made up of two separate power supply units coupled in a single
chassis.
Refer to:
Table 2 on page 9 for tabular listing of power supply LEDs indicators and Figure 9 below.
This module has:
  Two “Power” red-colored pushbutton switches - Push in for ON and release out for OFF. Control
complete power distribution to the Radio assembly
  Two “ON” LEDs - light green when push button(s) is (are) ON; DC power is distributed to radio
modules. Flash green in conjunction with the “OL” LED (flashing red) when an over voltage
condition is present.
  Two “Stby”- Standby voltage LED, lights red when push button is off; AC power is applied but
DC is not distributed to radio modules. To remove presence of voltage, disconnect both power
cords.
  Two “OL” LEDs - Monitor current overload, light steady red when supply exceeds current limit
set; nominally 25Amps (T808 model). Flashes red in conjunction with the ON LED (flashing
green) when an over voltage condition is present.
Figure 9 - Dual Power Supply Module front panel
OL Stby
On
Power
OL Stby
On
Power
T800
 II
 Slimline
®
Dual Power Supply  Module