 Paragon-III Technical Manual
 
14
 
3.1.6  Dual Power Supply module 
The Dual Power Supply module is made up of two separate power supply units coupled in a single 
chassis.  
Refer to: 
Table 2 on page 9 for tabular listing of power supply LEDs indicators and Figure 11 below. 
This module has: 
•  Two “Power” red-colored pushbutton switches - Push in for ON and release out for OFF. Control 
complete power distribution to the Radio assembly 
•  Two “ON” LEDs - light green when push button(s) is (are) ON; DC power is distributed to radio 
modules. Flash green in conjunction with the “OL” LED (flashing red) when an over voltage 
condition is present. 
•  Two “Stby”- Standby voltage LED, lights red when push button is off; AC power is applied but 
DC is not distributed to radio modules. To remove presence of voltage, disconnect both power 
cords. 
•  Two “OL” LEDs - Monitor current overload, light steady red when supply exceeds current limit 
set; nominally 25Amps (T808 model). Flashes red in conjunction with the ON LED (flashing 
green) when an over voltage condition is present. 
Figure 11 - Dual Power Supply Module front panel 
OL Stby On
Power
OL Stby On
Power
T800 II Slimline
®
Dual Power Supply Module