14
3.1.6 Dual Power Supply module
The Dual Power Supply module is made up of two separate power supply units coupled in a single
chassis.
Refer to:
Table 2 on page 9 for tabular listing of power supply LEDs indicators and Figure 11 below.
chassis.
Refer to:
Table 2 on page 9 for tabular listing of power supply LEDs indicators and Figure 11 below.
This module has:
• Two “Power” red-colored pushbutton switches - Push in for ON and release out for OFF. Control
• Two “Power” red-colored pushbutton switches - Push in for ON and release out for OFF. Control
complete power distribution to the Radio assembly
• Two “ON” LEDs - light green when push button(s) is (are) ON; DC power is distributed to radio
modules. Flash green in conjunction with the “OL” LED (flashing red) when an over voltage
condition is present.
condition is present.
• Two “Stby”- Standby voltage LED, lights red when push button is off; AC power is applied but
DC is not distributed to radio modules. To remove presence of voltage, disconnect both power
cords.
cords.
• Two “OL” LEDs - Monitor current overload, light steady red when supply exceeds current limit
set; nominally 25Amps (T808 model). Flashes red in conjunction with the ON LED (flashing
green) when an over voltage condition is present.
green) when an over voltage condition is present.
Figure 11 - Dual Power Supply Module front panel
OL Stby On
Power
OL Stby On
Power
T800 II Slimline
®
Dual Power Supply Module