Section 2.3: Changing Other NT9010 Functions
Most installations will only require basic programming. You can complete the basic programming using the 
NT9010’s Flash Programming (please see Chapter 1: Quick Set Up for more information). This section explains 
programmable features that affect the internal functioning of the system, including zone operation, central sta-
tion communications, talk/listen-in features, computer downloading features, and other advanced options.
2.3.1
Zone 
Definitions
You can change how each of the 32 zones will operate in programming sections 
[001] - [004]. For each zone that will be used, enter a 2-digit zone definition.
NOTE:
In addition to selecting how each zone will operate, attributes 
may be programmed by zone (see 2.3.2 Zone Attributes on page 38).
NOTE:
PIR’s covering entry/exit zones should be type [06] Delay Stay/Away.
[00]
Null Zone: The zone will not operate in any way. Zones that are not used 
should be programmed as Null zones.
[01]
Delay 1 Zone: If this zone is violated when the system is armed it will pro-
vide an entry delay. The keypad buzzer will sound to warn the user that the 
system must be disarmed. If the system is not disarmed before the entry 
delay expires an alarm will be generated. Typically this type of zone will be 
used for the front door, back door or any other entry/exit point. Refer to 
Section [005], “System Times”, to program the Delay 1 zone entry delay 
time.
[02]
Delay 2 Zone: This zone type operates the same as the Delay 1 zone option 
but can provide a different entry delay. Typically this zone will be used for a 
garage door. Refer to Section [005], “System Times”, to program the Delay 
2 zone entry delay.
[03]
Instant Zone: If this zone type is violated when the system is armed it will 
cause an instant alarm. Typically this zone is used for windows, patio doors 
or other perimeter type zones.
[04]
Interior Zone: If this type of zone is violated when the system is armed it 
will follow entry delay if a delay type zone was violated first. Otherwise it 
will cause an instant alarm. Typically this zone is used for interior protection 
devices, such as motion detectors.
[05]
Interior Stay/Away Zone: This zone type works the same as the Interior 
zone type with one exception. The zone will be automatically bypassed 
under the following conditions:
the system is armed in the Stay Mode (see 2.2.10 Function Keys on 
page 31)
the system is armed without entry delay (see [*] [9] Arming Without 
Entry Delay
 on page 30)
the system is armed with an access code and during the exit delay a Delay 
type zone is NOT tripped
The automatic bypass avoids having the user manually bypass interior type 
zones when arming at home. If automatically bypassed, the user can reacti-
vate the zones by entering the [✱][1] command (see [*] [1] Zone Bypass-